Workshop Manuals Factory service & repair Volkswagen
01 4-cyl. injection engine with timing chain02 4-cyl engine03 Fault finding; Power transmission04 5-speed manual gearbox 02T05 6-speed automatic gearbox 09G06 09G Gearbox07 02R Gearbox08 02T Gearbox09 Brake systems10 Wheels and Tyres Guide: Standard11 Running gear; axles; steering12 Running gear, axles, steering13 Brakes14 Wheels and Tyres Guide15 Heating; air-conditioning16 Electrical: General Information17 Electrical: Communication18 Electrical19 General body repairs, exterior20 General body repairs, interior21 Body Interior
Volkswagen Polo Vivo, South Africa (2010-2017)18 · Electrical
18 · Electrical

Expansion valve, function and removal

Make
Volkswagen
Model
Polo Vivo, South Africa
Year
2010–2017
Section
Wiring harness and connector repairs › Expansion valve, function and removal
ElectricalExpansion valve, function and removal

Expansion valve, function and removal

Note

  • The refrigerant must be extracted beforehand, e.g. with air conditioning service station VAS 6007A.
  • The previously used service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
  • Only the components marked with an * can be renewed without opening and evacuating the refrigerant circuit.
  • To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.

N87-0671
  • Seal between evaporator housing and bulkhead*
  • O-ring
    11.10 mm; 1.78 mm
  • Expansion valve
    Aperture must be sealed against splashed water.FunctionThe expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.RemovingFirst carry out the following work:Evacuate refrigerant circuit, for example, with air conditioning service station VAS 6007A before opening it.NoteReleasing refrigerant into the environment is a punishable offence.WARNINGDanger of freezing injuries.If refrigerant circuit has not been evacuated, refrigerant will escape.Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again.Remove bolts (8).Pull out refrigerant line (5) and refrigerant hose (6).Renew O-rings (4) and (9).Remove bolts (7).Remove expansion valve (3).Renew O-rings (2) and (10).
  • O-ring
    10.8 mm; 1.82 mm
  • Refrigerant line
    From receiver with dryer cartridge to expansion valve.
  • Refrigerant hose
    From expansion valve to air conditioner compressor.
  • Socket head combi-bolt
    5 Nm
  • Bolts
    12 Nm
    Qty. 2
  • O-ring
    14.30 mm; 2.40 mm
  • O-ring
    17.17 mm; 1.78 mm

Parts & tools for this job For 2010 Volkswagen Polo