Workshop Manuals Factory service & repair Volkswagen
01 4-cyl. injection engine with timing chain02 4-cyl engine03 Fault finding; Power transmission04 5-speed manual gearbox 02T05 6-speed automatic gearbox 09G06 09G Gearbox07 02R Gearbox08 02T Gearbox09 Brake systems10 Wheels and Tyres Guide: Standard11 Running gear; axles; steering12 Running gear, axles, steering13 Brakes14 Wheels and Tyres Guide15 Heating; air-conditioning16 Electrical: General Information17 Electrical: Communication18 Electrical19 General body repairs, exterior20 General body repairs, interior21 Body Interior
Volkswagen Polo Vivo, South Africa (2010-2017)18 · Electrical
18 · Electrical

Renewing refrigerant circuit components

Make
Volkswagen
Model
Polo Vivo, South Africa
Year
2010–2017
Section
Wiring harness and connector repairs › Renewing refrigerant circuit components
ElectricalRenewing refrigerant circuit components

Renewing refrigerant circuit components

Warning Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant will escape.
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again.

Note

  • The refrigerant must be extracted beforehand, e.g. with air conditioning service station VAS 6007A or later models.
  • The previously used service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
  • Safety measures when working on an evacuated refrigerant circuit → Chapter.
  • To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
  • The colour coding of O-rings for R134a refrigerant circuits has been discontinued. Coloured and black O-rings are used.
  • It is not necessary to renew the dryer cartridge each time the refrigerant circuit is opened Rep. gr.00Technical data in "Air conditioning system with refrigerant R134a VW"; “Renewing components”.
  • Only the components marked with an * can be renewed without opening and evacuating the refrigerant circuit.

N87-0692
  • High pressure sender G65*
    Removing and installing → Chapter
  • Socket head combi-bolt
  • Expansion valve
    Function and removal → Chapter.
  • O-ring
    17.17 mm; 1.78 mm
  • O-ring
    11.10 mm; 1.78 mm
  • O-ring
    10.8 mm; 1.82 mm
  • O-ring
    14.30 mm; 2.40 mm
  • Refrigerant line
  • Evaporator
    In passenger compartment
    Removal → Chapter, Dismantling and assembling the evaporator housing.
  • Threaded plate
  • Extraction and charging valve
    High-pressure side
    Releasing refrigerant into the environment is a punishable offence.
    Removing and installing → Fig.
    Capacities → Chapter
    7 Nm
  • Socket head combi-bolt
    12 Nm
  • O-ring
    14.3 mm; 2.4 mm
  • Socket head combi-bolt
    22 Nm
  • Air conditioner compressor
    Observe running-in procedures → Chapter.
  • O-ring
    10.8 mm; 1.82 mm
  • Condenser
    Removing → Chapter
  • O-ring
    10.8 mm; 1.82 mm
  • Socket head combi-bolt
    22 Nm
  • Receiver with dryer cartridge
    Functions → Chapter.
    Removing dryer cartridge ChapterNoteIt is not necessary to renew the dryer cartridge each time the refrigerant circuit is opened Rep. gr.00Technical data in "Air conditioning system with refrigerant R134a VW"; “Renewing components”.
  • Socket head combi-bolt
    12 Nm
  • O-ring
    10.8 mm; 1.82 mm
  • Refrigerant hose
  • Quick release coupling
    Removing and installing → Chapter
  • Extraction and charging valve
    Low-pressure side
    Releasing refrigerant into the environment is a punishable offence.
    Removing and installing → Fig.
    Capacities → Chapter.
    7 Nm
  • Quick release coupling
    Removing and installing → Chapter
Removing extraction and charging valve, low-pressure side
V87-1434

Warning Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant will escape.
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again.

Extract refrigerant using, for example, air conditioner service station VAS 6007A before renewing valve (3).

Note

  • Releasing refrigerant into the environment is a punishable offence.
  • All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.

1Connection with external thread and groove for O-ring2O-ring; 7.6 mm; 1.8 mm3Extraction and charging valve4O-ring5CapRemoving extraction and charging valve, high-pressure side
V87-1435

Warning Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant will escape.
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again.

Extract refrigerant using, for example, air conditioner service station VAS 6007A before renewing valve (3).

Note

  • Releasing refrigerant into the environment is a punishable offence.
  • All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.

1Connection with internal thread2O-ring; 10.8 mm; 1.8 mm3Extraction and filling valve with groove and internal thread for cap.4O-ring5Cap

Parts & tools for this job For 2010 Volkswagen Polo