Do not start engine until after reconnecting refrigerant circuit.
After installing a new air conditioner compressor or filling with fresh refrigerant oil (e.g. after blowing out refrigerant circuit), turn compressor pulley 10 revolutions by hand before starting engine.
This will prevent damage to the air conditioner compressor.
If possible, start engine only with refrigerant circuit charged.
Note
- The air conditioner compressor is driven permanently by the poly V-belt pulley (not fitted with a magnetic clutch).
- If an air conditioner compressor locks up, the overload protection for the compressor shaft is triggered. A seized air conditioner compressor cannot always be identified by visible deformations in the poly V-belt pulley. Another indication is abraded rubber material in the area of the poly V-belt pulley.
- The air conditioner compressor has an internal oil circuit to ensure that the air conditioner compressor is not damaged when the refrigerant circuit is empty. This means that about 40 to 50 cm3 refrigerant oil remain in the air conditioner compressor.
- The engine may be started only when the refrigerant circuit is properly assembled. If, for example, the refrigerant lines are not connected to the air conditioner compressor and the engine is running, the compressor may heat up so much through internal warming that it will be destroyed.
- As there is no refrigerant in the circuit, the oil required for lubrication is not transported to the compressor.
- Air conditioning system compressor regulating valve N280 is not activated when the refrigerant circuit is empty and the air conditioner compressor idles with the engine.
- If it is necessary to start engine with an empty refrigerant circuit:
- The refrigerant circuit must be fully assembled.
- At least 1/4 of the quantity of refrigerant oil specified for this refrigerant circuit must be in the air conditioner compressor.
- The engine speed must not exceed 2500 rpm.
- Run engine only as long as absolutely necessary.
Note
- Note the following when starting engine for first time after filling refrigerant circuit:
Start engine with air conditioner compressor switched off and wait until idling speed is stable.
Open dash panel vents.
Now switch on air conditioner and allow engine to idle for at least 5 minutes.