01 3 - Cyl. injection engine02 3 - Cyl. injection engine (1.0l, turbocharger)03 Troubleshooting, Mechanical Transmission04 5 - Speed manual gearbox 0DF05 5 - Speed automated transmission 0CT06 Brake systems07 Running gear, axles, steering08 Wheels and Tyres - Specifications09 Heating, air conditioning10 Electrical system11 Electrical: Communication12 General body repairs, interior13 General body repairs, exterior
Volkswagen Brazil-market up! (2014-2021)09 · Heating, air conditioning
09 · Heating & A/C

Expansion valve - remove and install

Make
Volkswagen
Model
Up! Brazil-market up!
Year
2014–2021
Section
Coolant gas loop › Expansion valve - remove and install
Heating, air conditioningExpansion valve - remove and install

Expansion valve - remove and install

Special tools and workshop equipment required"Torque wrench - 5 to 50 Nm (fit. 1/2"")" VAG 1331
W00-11166
Service station for air conditioning VAS 6007A or newer model.
W00-10176
Climate control recovery, recycling, refilling, and cleaning system EQ 7111
R87-10075

Note

  • The refrigerant must be previously aspirated with the Climate control recovery, recycling, refilling, and cleaning system EQ 7111, for example.
  • All refrigerant circuit components that are open must be sealed with proper sealing plugs to prevent humidity from entering.

Remove

N87-0671
  • Seal between the evaporator housing and the front wall
  • Sealing ring
    Replace upon each removal
  • Expansion valve
    The passage must be protected against water spraying.The expansion valve sprays the refrigerant and regulates flow in order to allow steam to transform into gas only on the evaporator output, depending in heat flow.
  • Sealing ring
    Replace upon each removal
  • High pressure tubes
  • Low pressure tubes
  • Screws
    5 Nm
    2 units
  • Screws
    12 Nm
    2 units
  • Sealing ring
    Replace upon each removal
  • Sealing ring
    Replace upon each removal

Initially carry out the following tasks:

Aspirate the refrigerant circuit with the Climate control recovery, recycling, refilling, and cleaning system EQ 7111, for example, and only then open the refrigerant circuit.

Note

  • Contaminating the environment with refrigerant is a punishable offence.

Warning Risk of pressurized effluent refrigerant!
Risk of freezing the skin and other body parts.
Remove the refrigerant via suction and open the refrigerant circuit.If suction was carried out over 10 minutes and the refrigerant circuit is still not opened, repeat the refrigerant suction process. Re-evaporation creates pressure in the refrigerant circuit.

Remove the screws (8).

Disconnect the refrigerant hoses (5) and (6).

Remove the screws (7).

Remove the expansion valve (3).

Install

  • Replace sealing rings (2), (4), (9) and (10).

Installation is performed in reverse sequence to the removal.

Parts & tools for this job For 2014 Volkswagen Up!

As an Amazon Associate we earn from qualifying purchases.