Service valves - remove and install
- Make
- Volkswagen
- Model
- Up! Brazil-market up!
- Year
- 2014–2021
- Section
- Coolant gas loop › Service valves - remove and install
Service valves - remove and install
Special tools and workshop equipment requiredAspirate the refrigerant using the service station for air conditioning VAS 6007A or newer model, for example.




Note
- The refrigerant must be previously drained with the service station for air conditioning VAS 6007A (or newer model).
- Contaminating the environment with refrigerant is a punishable offence.
Remove the protection caps (3) and (4) (2 ± 0.2 Nm).

Aspirate the refrigerant circuit with the service station for air conditioning VAS 6007A, for example, and only then open the refrigerant circuit.
Warning Risk of pressurized effluent refrigerant!
Risk of freezing the skin and other body parts.
Remove the refrigerant via suction and open the refrigerant circuit.If suction was carried out over 10 minutes and the refrigerant circuit is still not opened, repeat the refrigerant suction process. Re-evaporation creates pressure in the refrigerant circuit.
Remove the service valves (1) and (2) (2.4 ± 0.2 Nm) with the Fitting insertion T10364 and appropriate adapter.
Installation is performed in reverse sequence to the removal.
Parts & tools for this job For 2014 Volkswagen Up!
- PARTEngine gasket setSearch: Volkswagen Up! 2014 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.