Page 4
background image

Note:
Ensure that guide pin is located in heater housing.

Tighten in position using five countersunk screws (Torx T20) and ensure that gasket is correctly positioned.

Drill 18 mm (11/16") hole in fan housing using hole saw with adapter as template. Remove all plastic shavings.

Install new connector

Cut cable lugs off existing wires.

Attach two new cable lugs (p/n 949680-3). Press lugs home into connector with black-white wire connected to connector wires (pin 2).

If there are no further modifications needed, refer to "Installation".

MODIFICATION B (modifying blower motor cover to fit wiring connector):

Measures to be carried out when replacing motor

Cut out cover as illustrated to provide clearance between cover and connector. Illustration shows cut-out as viewed from outside cover.