940 L4-2.3L SOHC VIN 88 B230F (1992)
Install blower motor in fan housing and tighten 3 screws (arrows).
Connect connector to blower motor.
Note:
If suppressor harness is fitted between wiring harness and blower motor, the harness can be removed since the blower motor is now internally
suppressed.
Install:
-
control unit mounting bracket
-
control unit and connector
Reconnect battery.
Air leakage test
Run blower motor at high speed to blow out any loose remaining debris.
Feel for leakage around connector.