Route green cables with single round or flat terminals to engine compartment through unused outlet in grommet under brace to suspension strut
(tower).

-

Connect round or flat connectors to corresponding existing connectors.

-

Connect unconnected connectors together.

E4

Location of opening in cable sheath

The cable sheath is cut to drain off condensation.

-

The cut conduit section should be placed at the lowest point in the cable routing.

Use bury tape to seal the grommet.
-

Use existing clamps to clamp up the cables to firewall.

E5

Connection of yellow connector

-

Disconnect the yellow connector from the heater and attach the yellow connector from the new cable harness.

-

Connect the detached yellow connector to the yellow connector on the cable harness

Installation of control module from kit.

E6

Connection and mounting of control module