volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

A/C - Unpleasant Odor From Ventilation System|Page 10958 > < A/C - Unpleasant Odor From Ventilation System
Page 2
background image

- Check the evaporator is clear. Clear drain if required.
- Place a small container under the evaporator drainage. Place it on the right front member.

A2

START ENGINE AND RUN UP TO WORKING TEMPERATURE.

- Select recirculation, set temperature control to max. heat and select max. blower speed. All ventilation outlets should be fully open.

- Turn off A/C compressor by disconnecting the cable terminal (see arrow) from the pressure switch (pressostat) in the engine compartment.

NOTE!

If the defroster position is selected on the control panel then the compressor is under override control and will start up.

- Start engine.

Allow engine to run at operating temperature for 20 minutes to expel all moisture from evaporator.

Carry out operation A3 while running engine up to temperature.

A3

PREPARE AS2 NOZZLE ASSEMBLY

- Shake bottle well

- Remove cap and attach bottle to nozzle (rubber hose attached in previous step)

- Attach nozzle to shop air gun. Use 80 120 psi air pressure.

A4

A/C - Unpleasant Odor From Ventilation System|Page 10958 > < A/C - Unpleasant Odor From Ventilation System