Attach cable harness and the relay using 2 strip clamps in the foam plastic covered hose which passes over the glove compartment to the side
defroster, one clamp as near as possible to the connector to prevent noise caused by vibration from uneven road surfaces.

D11

Connection to ground plate

-

Connect the black-white cable included in the cable harness to the ground plate on the right side of the cowl.

The ground plate is behind the fuel control module.

Function verification and information

D12

Check airing cycle is working 

-

Connect battery lead and start car 

-

Turn A/C system on so the compressor starts

The A/C system starts if the temperature exceeds approx. 7°C (45° F).
-

Make up a cable approx. 2 meters (6.5 ft) in length to connect battery positive terminal to the connector on the control module. Connect to green
cable connector terminal 6, for at least 30 seconds while compressor is working.

-

Turn off engine.

Airing cycle should begin after approx 10 seconds and continue for approx. 1 second.

A/C - Odor From The Ventilation System|Page 10894 > < A/C - Odor From The Ventilation System|Page 10892