Relays and Modules > Relays and Modules - HVAC > Control Module HVAC > Component Information > Technical Service Bulletins > All Technical Service Bulletins for Control Module HVAC: > 887955 > Sep > 97 > A/C - Unpleasent Odor On Startup > Page 453

Page 30
background image

G7
Check airing cycle is working
-

Connect battery lead and start car.

-

Turn on A/C system to start compressor.

The A/C system starts if the temperature exceeds approx. 7°C (45°F).
-

Make up a cable (about 2 meters in length) to connect battery positive terminal to control module connector.

Connect to green cable, connector terminal 6, for at least 30 seconds while compressor is operating.
-

Turn off engine.

Airing cycle should begin after approximately 10 seconds and continue for approximately 1 second.
-

Remove cable between connector and battery.

G8
Fastening cables
-

Clamp cable harness in position using tie straps on the front of the air duct below glove compartment.

-

Use the eyelet on the connector to fasten the tie straps.

-

Clamp cable harness in position using the straps on the front of the air duct above glove compartment (not shown in illustration).

-

Use the eyelet on the connector to fasten the tie straps.