K07 Odometer fails to switch to outside temperature (Automatic air conditioner)
- Make
- Alfa Romeo
- Model
- 156 Factory Service Manual
- Year
- 1997–2002
- Section
- Instruments › K07 Odometer fails to switch to outside temperature (Automatic air conditioner)
K07 Odometer fails to switch to outside temperature (Automatic air conditioner)
With the ignition key in the ON position, the speedometer works properly, but does not manage to switch to the outside temperature reading.
| Step | Test procedure | Result | Action |
|---|---|---|---|
| 0 | PRELIMINARY CHECKS Check the operation of the speedometer | OK | |
| The speedometer is not working at all | Move onto step (see K05) | ||
| 1 | ZEROING BUTTON CHECK Check the operation of the speedometer zeroing button | OK | |
| Zeroing button faulty |
End of diagnosis | ||
| 2 | OUTSIDE TEMPERATURE SIGNAL ELECTRICAL CIRCUIT CHECK Check, in order:
| OK | |
| Connections broken |
End of diagnosis | ||
| 3 | CHECK WITH DIAGNOSTIC EQUIPMENT Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check that there are no faults in the climate control unit, in particular check the outside temperature sensor and the signal | OK | |
| Signal not sent |
End of diagnosis | ||
| Climate control unit faulty |
End of diagnosis | ||
| 4 | SPEEDOMETER CHECK Check the operation of the speedometer, in particular the outside temperature display function: see DESCRIPTION AND OPERATION: 5560 Instruments (see 5560F) | OK | |
| Instrument not working |
End of diagnosis | ||
| 5 | CHECK CORRECT OPERATION Check that the fault is no longer present | OK | End of diagnosis |
| Fault persists | Incorrect selection of diagnostic procedure |
Parts & tools for this job For 1997 Alfa Romeo 156