Workshop Manuals Factory service & repair Alfa Romeo
01 General data and specifications02 Engine (Twin Spark, JTD and V6)03 Clutch04 Gearbox (manual, Selespeed and Q-System)05 Front axle06 Brakes, ABS and traction control07 Steering08 Suspension and wheels09 Heating, air conditioning and washers10 Electrical equipment11 Body12 Body panels and reinforcement13 Wiring diagrams14 Connectors and pin-outs15 Wiring harnesses16 Fault diagnosis17 Special tools
Alfa Romeo 156 Factory Service Manual (1997-2002)16 · Fault diagnosis
16 · Diagnostics

K63 Handbrake warning light off (initial test not run)

Make
Alfa Romeo
Model
156 Factory Service Manual
Year
1997–2002
Section
Instruments › K63 Handbrake warning light off (initial test not run)
Fault diagnosisK63 Handbrake warning light off (initial test not run)

K63 Handbrake warning light off (initial test not run)

On starting, the "handbrake" warning light does not come on (it should come on for 2 seconds to indicate the initial test of the control unit, and then go out)

NOTA: The "low brake fluid" and "handbrake on" warning light, it also indicates an EBD function fault if it comes on at the same time as the ABS warning light

StepTest procedureResultAction
1CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket

Check that there is a regular dialogue with the ABS control unit

OK

Move onto step 2

Lack of dialogue with the control unit

Restore:

End of diagnosis

An error is detected in the control unit
  • Continue according to the instructions for the diagnostic equipment

End of diagnosis

2CHECKING CHECK CONTROL POWER SUPPLY

Check, in order:

  • connection between ABs control unit and check control instrument.
  • supply to check control instrument

(Wiring diagram E4022 CENTRAL INSTRUMENT (CHECK) ).

OK

Move onto step 3

Connections not correct
  • Restore the connections

End of diagnosis

Component defective
  • Replace the component involved (if a fuse is involved, search for the cause of the problem)

End of diagnosis

3CHECK CONTROL CHECK

Check the operation of the check control instrument see DESCRIPTION AND OPERATION: 5560 Instruments (see 5560F)

OK

Move onto step 4

Instrument not working

End of diagnosis

4CHECK CORRECT OPERATION

Check that the fault is no longer present

OK

End of diagnosis

Fault persists

Incorrect selection of diagnostic procedure

Parts & tools for this job For 1997 Alfa Romeo 156

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.