Workshop Manuals Factory service & repair Alfa Romeo
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

P0111 - debimeter air temperature signal

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Examiner - diesel electronic management › P0111 - debimeter air temperature signal
Fault diagnosisP0111 - debimeter air temperature signal

P0111 - DEBIMETER AIR TEMPERATURE SIGNAL

2.4 JTD 20v

The diagnostic equipment signals: Error P0111 (flow meter air temp. signal).

This error is detected if there is interference with the signal for the sensor at Pin 37 of the electronic control module (detail "general electrical fault") or if there is a short circuit to positive (detail "beyond the upper limit") or to earth (detail "below the lower limit") in the circuit connected to Pin 37 of the control unit. In the case of short circuits, the control unit takes 25 °C as the replacement value.

1FLOW METER OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check that the flow meter is working properly by carrying out the

See Test 1060GS DEBIMETER OPERATION CHECK

End of diagnosis