01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

P0685 - main relay (actuator slip)

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Examiner - diesel electronic management › P0685 - main relay (actuator slip)
Fault diagnosisP0685 - main relay (actuator slip)

P0685 - MAIN RELAY (ACTUATOR SLIP)

2.4 JTD 20v

The diagnostic equipment signals: Error P0685 (main relay), with detail "actuator slipping"

This error is detected if the main relay switches off too late or does not switch off at all. If the main relay is not switched off after the control units have been inactive for a while, a counter is activated in the engine management control unit. If the main relay is not switched off after an internally programmed period, the fault code is issued.

1Check on operation of main relayALL OKPROBLEMS ENCOUNTEREDACTION

Check that the main relay is working properly by carrying out the test

See Test 1060GL CHECK OPERATION OF MAIN ENGINE CONTROL UNIT RELAY

End of diagnosis