Workshop Manuals Factory service & repair Alfa Romeo
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

P0697 - sensor power supply 3

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Examiner - diesel electronic management › P0697 - sensor power supply 3
Fault diagnosisP0697 - sensor power supply 3

P0697 - SENSOR POWER SUPPLY 3

2.4 JTD 20v

The diagnostic equipment signals: Error P0697 (Sensor power supply 3).

This error is detected if there is a short circuit to positive (detail "beyond the upper limit") or a short circuit to earth or a break (detail "below the lower limit") in the circuit connected to Pin 22, or 44 of the junction unit.

1Junction unit connections checkALL OKPROBLEMS ENCOUNTEREDACTION

Check that the engine management control unit connections are correct by carrying out the test

See Test 1060GP CHECK ENGINE CONTROL UNIT CONNECTIONS

End of diagnosis

Parts & tools for this job For 2005 Alfa Romeo Brera