Battery handling instructions
Battery handling instructions
Note
t
Battery terminals should now NOT be greased.
t
To avoid damaging the battery housing, do not use force when attaching the battery clamps; press them on by hand.
t
The tightening torque for the battery clamps
-2-
is 8 Nm.
t
The tightening torque for the additional clamps
-1-
at the battery terminal clamps is 7.5 Nm.