Re-pressurising: CNG supply circuit
- Make
- Citroën
- Model
- Jumper II Factory Workshop Manual
- Year
- 2002–2006
- Section
- Engine assembly › Re-pressurising: CNG supply circuit
Re-pressurising: CNG supply circuit
CAUTION: A gas leak may occur in the natural gas supply circuit at low pressure and disappear at high pressure and vice versa. Therefore, it is necessary to check for leaks at different pressures.
ESSENTIAL: Never re-tighten or unscrew connectors under pressure.
N.B.: Before refitting the components, check that no foreign body has entered the ducts or is on the mesh of the connectors.
1. Recommended tools
[1] leak detector FRAMET DF9.
2. Re-pressurising
Close the natural gas supply circuit again and re-tighten the connectors.
N.B.: Close the manual safety valves at "a" located on the CNG tanks.
2.1. Stage 1
Spray the product from tool [1] onto the previously removed unions (failing that, use soapy water).
Open then rapidly close one CNG tank manual safety valve at "a".
Run the engine in natural gas mode until it changes to petrol mode.
Stop the engine.
Check for any leaks at the CNG unions (presence of bubbles) using tool [1], or soapy water.
ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.
CAUTION: Wait a few minutes, then perform a new check Using tool [1].
2.2. Stage 2
Spray the product from tool [1] onto the previously removed unions (failing that, use soapy water).
Open then rapidly close one CNG tank manual safety valve at "a".
Run the engine in CNG mode until the pressure reaches around 50 ± 10 bars.
Stop the engine.
N.B.: To obtain this pressure, connect the diagnostic tool to the vehicle then read the pressure in the CNG circuit Close a manual safety valve at "a" when the value of 50 bars is reached.
Without diagnostic equipment (see the relevant operation).
Check for any leaks at the CNG unions (presence of bubbles) using tool [1], or soapy water.
ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.
CAUTION: Wait a few minutes, then perform a new check Using tool [1].
Achieving a defined pressure.
N.B.: The electrical check is carried out using a shunt (2) to be placed between the CNG pressure sensor (1) and its connector (3). The output signal is registered using a multimeter on the terminal "b".
V: Voltage (V).
P: Pressure (bars).
The table indicates the relation between the pressure and the output voltage: 1 V for 50 bar.
2.3. Stage 3
Open the 3 CNG tank manual safety valves at "a".
Run the engine in CNG mode until the pressure reaches around 100 bars.
N.B.: To obtain this pressure, connect the diagnostic tool to the vehicle then read the pressure in the CNG circuit.
Check for any leaks at the CNG unions (presence of bubbles) using tool [1], or soapy water.
ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.
CAUTION: Wait a few minutes, then perform a new check Using tool [1].
2.4. Stage 4
N.B.: This stage must be carried out at a pressure of 200 bars, therefore the CNG tanks must be filled to maximum capacity. If this is not the case, top up at the closest natural gas station.
Open the 3 CNG tank manual safety valves at "a".
Run the engine in natural gas mode.
Check for any leaks at the CNG unions (presence of bubbles) using tool [1], or soapy water.
ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.
After an idle phase of at least 3 hours, carry out a final detection of leaks before supplying to the customer.
3. Additional operations
After using a surface-active agent (leak detector or soapy water) on a union, the unions must be rinsed with clean water and dried using compressed air Risk of corrosion.
Parts & tools for this job For 2002 Citroën Jumper
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.