01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Ducato Factory Service Manual (2002-2006)16 · Heating, air conditioning and auxiliary units
16 · Heating & A/C

Independent heater unit - r r

Make
Fiat
Model
Ducato Factory Service Manual
Year
2002–2006
Section
Heater › Independent heater unit - r r
Heating, air conditioning and auxiliary unitsIndependent heater unit - r r

INDEPENDENT HEATER UNIT - R R

Operation 5020M10 · SUPPLEMENTARY INDEPENDENT HEATER

Removing

- Disconnect the negative battery terminal.

- Raise the vehicle on a lift.

- Position a suitable container for collecting the fuel.

- Position a suitable container for collecting the coolant.

1. Support the weight of the heater unit and undo the bolts (1a) and the nuts (1b) fixing the independent heater unit mounting bracket.

INDEPENDENT HEATER UNIT - R R

1. Disconnect the fuel inlet pipe loosening the fastening band.

2. Disconnect the coolant inlet and outlet pipes loosening the fastening bands.

Mark one of the two pipes to prevent them being incorrectly connected when refitting.

3. Disconnect the electrical connector for the independent heater unit and release it from the mounting bracket.

DescriptionConnector
3Additional heater control unitM075

- Remove the independent heater unit.

INDEPENDENT HEATER UNIT - R R

Refitting

- Connect the electrical connector for the heater unit.

DescriptionConnector
Additional heater control unitM075

- Connect the engine coolant inlet and outlet pipes to the independent heater unit using the special fastening bands.

- Connect the fuel supply pipe to the independent heater unit using the special fastening band.

- Secure the independent heater unit support to the bodyshell tightening the nuts and bolts to the recommended torque.

Value - daNmFasteningComponentØ
2NutADDITIONAL HEATER BOILERM8
Value - daNmFasteningComponentØ
2BoltADDITIONAL HEATER BOILERM8

- Lower the vehicle on the lift.

- Connect the negative battery terminal.