Install or Connect

1. Dip the new seal O-ring in clean 525 viscosity refrigerant oil and assemble Onto O-ring installer J 33011. "New".
2. Insert the O-ring installer J 33011 into the compressor neck until the installer "bottoms." Lower the moveable slide of the O-ring installer to

release the O-ring into the seal O-ring lower groove. (The compressor neck top groove is for the shaft seal retainer ring.) Rotate the installer to seat
the O-ring and remove the installer.

3. Dip the new seal in clean 525 viscosity refrigerant oil and assemble seal to Seal Installer J 23128-A, by turning handle clockwise. The stamped

steel case side of the lip seal must be engaged with knurled tangs of installer so that flared-out side of lip seal is facing and installed towards the
compressor. Install shaft seal protector J 34614 on the lip seal. Place the seal protector J 34614 over end of compressor shaft, and slide the new
seal onto the shaft with a rotary motion until it stops. Take care not to dislodge the O-ring. Be sure the seal makes good contact with the O-ring.
Disengage the installer from the seal and remove the installer J 23128-A and the shaft seal protector J 34614.

NOTE:  Handling and care of seal protector is important. If seal protector is nicked or the bottom flared, the new seal may be damaged during
installation.