Refit
- Position matrix to casing.
- Align casing halves and secure with clips.
- Insert tip of thermocouple into centre of matrix fins.
- Position servo output crank to recirculation flap lever and secure servo with screws.
- Fit NEW foam seal to output duct.
- Position evaporator, fit nuts but do not tighten.
- Engage hose to drain pipe.
- Fit clamp securing evaporator to heater and tighten nut to 3 Nm.
- Tighten nuts securing evaporator to lower dash panel to 9 Nm.
- Connect multiplugs.
- Remove evaporator pipe caps and clean air conditioning pipe connections.
- Lubricate NEW ’O’ rings with refrigerant oil.
- Fit pipe bracket to evaporator pipes.
- Fit thermostatic expansion valve. See this section.
- Fit fascia panel. See BODY, Interior trim components.
- Remove stand(s) and lower vehicle.