porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Procedures|Page 4528 > < Procedures|Page 4526
Page 2
background image

levelling system menu item in the Levelling system.

2. Fit protective tube on drive shaft (shop-made to protect the drive shaft).
3. Loosen pressure line on residual pressure retaining valve -arrow- using insert part T10212 (front spring strut connection in figure). Then, unclip

the pressure line from the holders and set it aside.

4. Remove stone guard for CDC sensor -arrow-.

5. Disconnect CDC sensor plug connection -arrow-, remove the cable from the holder, and set the cable aside.

Procedures|Page 4528 > < Procedures|Page 4526