skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Ignition system, glow plug system > < Removing and installing radiator for exhaust gas recirculation
Check changeover of radiator for exhaust gas recirculation
Check changeover of radiator for exhaust gas recirculation
Special tools and workshop equipment required
t  Hand vacuum pump, e.g. -VAS 6213-
Work procedure
  Note
The vacuum setting element for change-over flap is accessible from below.
–  Remove the sound dampening system → Body Work; Rep. gr.50.
–  Unbolt heat shield for right drive shaft.
   
–  Detach vacuum hose from vacuum setting element.
–  Connect hand vacuum pump to vacuum setting element.
–  Actuate the hand vacuum pump in order to generate negative pressure.
l  The vacuum setting element must open the change-over flap up to the stop at maximum 0.08 MPa (0.8 bar) negative pressure and in case of ventilation close it up to the stop -arrows-.
  Note
t  For this test the opening of the change-over flap can be performed in jolts. In driving mode the change-over flap opens suddenly due to the large negative pressure volume.
t  The closing of the change-over flap must be carried out suddenly when ventilating (e.g. detach vacuum hose).
If the vacuum setting element does not open or close the change-over flap up to the stop:
–  Replace radiator for exhaust gas recirculation with vacuum setting element → Chapter.
  A26-10878

Ignition system, glow plug system > < Removing and installing radiator for exhaust gas recirculation