| Remove the connection pipes -A- to the cylinder head. |
–
| Remove oil feed and oil return-flow line with support for exhaust turbocharger → Chapter. |
–
| Collect the escaping engine oil with the old oil collecting and suction equipment -V.A.G 1782-. |
–
| Detach the vacuum line at the vacuum unit, Position 12 → Chapter. |
–
| Disconnect the plug connection at the electrical actuator of the exhaust gas recirculation valve -N18- for the radiator for exhaust gas recirculation. |
–
| Unclamp the coolant feed line and the return-flow line with the hose clamps up to Ø 25 mm -MP7-602 (3094)- on the radiator for exhaust gas recirculation. |
–
| Separate the coolant feed line and the return-flow line from the exhaust gas recirculation system. |
–
| Collect escaping coolant with the catch pan -VAS 6208-. |
–
| Release screws Position 5 → Chapter and remove the exhaust gas recirculation system. |
Installation is performed in the reverse order, pay attention to the following points: |
t
| Replace the gaskets, the sealing rings and the self-locking nuts. |
t
| Secure all hose connections with corresponding hose clips. |
–
| Inspect coolant level, top up with coolant if necessary → Chapter. |
|
|
|