Workshop Manuals Factory service & repair Skoda
01 Running gear02 Engine03 Body04 Drive unit05 Power transmission06 Vehicle electrics07 Heating, ventilation, air conditioning system08 Power unit09 Technical Data10 Self diagnosis, V.A.G Inspection Service11 Engine assy, cylinder block, crankcase12 Enginecrankshaft group, pistons13 Engine cylinder head, valve gear14 Engine lubrication15 Engine cooling16 Fuel supply, gas operation17 Exhaust turbocharger, G-charger18 Fuel preparation system Diesel injection19 Mixture preparation system, electronic inj., Gas20 Exhaust system21 Starter-current supply-CC22 Ignition system, glow plug system23 Clutch, control24 Torque converter25 Gearbox mechanics, operation, construction, diff.26 Gearbox, mechanics, gears, shafts, internal operation27 Automatic gearbox, control, assembly, housing28 Automatic gearbox, gears, control29 Final drive, differential, differential lock30 Front suspension, drive shafts31 Rear suspension, drive shaft32 Wheels, tyres. axle align33 ABS, ADR, TCS, EDL, ESP34 Brake, brake mechanics35 Brakes, hydraulics, regulator, servo36 Steering37 Body front38 Body centre, roof, frame39 Body, rear40 Sliding roof41 Exterior equipment42 Interior equipment43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
Skoda Roomster44 · Air conditioner
44 · Heating & A/C

Remove the refrigerant lines from the condenser

Make
Skoda
Model
Roomster
Section
Heating, Air conditioning › Remove the refrigerant lines from the condenser
Air conditionerRemove the refrigerant lines from the condenser

Remove the refrigerant lines from the condenser

Heating, ventilation, air conditioning system · Heating, Air conditioning · Repairing the air conditioning system - engine compartment · Superb II, Superb II from 2008 · Edition 01.2012

S87-0310

Note

  • Empty the refrigerant circuit with the aid of the A/C service station.
  • After disconnecting, shut off the refrigerant lines and the AC compressor connections with suitable caps to protect them from the penetration of ambient humidity.
1 Connection fitting for condenser 2 O-rings
  • Electronic Catalogue of Original Parts)
3 Connection fitting for refrigerant line
  • Torsion stop with sleeve
4 10 Nm5 Fitting sleeve6 Groove for O-ring

Note

  • After disconnecting, shut off the refrigerant lines and the condenser connections with suitable caps to protect them from the penetration of ambient humidity.

Parts & tools for this job For Skoda Roomster