Separating quick couplings for refrigerant lines
- Make
- Skoda
- Model
- Roomster
- Section
- Heating, Air conditioning › Separating quick couplings for refrigerant lines
Air conditionerSeparating quick couplings for refrigerant lines
Separating quick couplings for refrigerant lines
Note
- Repairs must only be carried out in specialist service centres which have suitably trained personnel and are fitted out for working on the refrigerant circuit.
- Release tool VAS 6127/3
- Circlip pliers
- Protective goggles
- Gloves
Note
- Whenever the quick coupling is disconnected, replace the O-ring, locking insert and circlip.
- These parts are available as repair kit (6Q0 298 260 - for high-pressure line; 6Q0 298 260A - for low-pressure line).
- The following describes the separating of the quick coupling of the low-pressure line. The work sequence for separating the quick couplings of the high-pressure line is the same.
Parts & tools for this job For Skoda Roomster
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Roomster cabin filter