skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Removing and installing parts of the secondary air injection system > < Removing and installing parts of the exhaust system
Secondary air system
Secondary air system
  WARNING
Please observe the following when undertaking all assembly work, particularly in the engine compartment, due to its cramped construction.
t  Lay lines of all kinds (e.g. for fuel, hydraulic fluid, the active charcoal container-unit, cooling fluid and refrigerent, brake fluid, vacuum) and electrical lines in such a way that the original line guide is re-established.
t  Ensure that there is adequate free access to all moving or hot components.
Operation
The secondary air injection system blows air in the escape valve for a short time during a cold start. This enriches the exhaust gas with oxygen, initiates a post-combustion and thus shortens the heating-up phase of the catalytic converter. Actuation is performed by the Motronic control unit -J220- through the secondary air pump relay -J299- to the secondary air injection valve (-N112- changeover valve) and combination valve.
   

Removing and installing parts of the secondary air injection system > < Removing and installing parts of the exhaust system