Taking measurement “e”
- Make
- Skoda
- Model
- Superb
- Section
- Manual gearbox 01E › Taking measurement “e”
Taking measurement “e”
Set the adjusting ring on the universal measuring rod VW 385/1 to measurement (a) = 65 mm.

Set the movable adjusting ring to measurement (b) = 65 mm.
Assemble universal measuring rod as shown in figure. Dial gauge extension VW 385/15 = 9.3 mm long. Set Universal master setting VW 385/30 to “Ro” = 59.65 mm, and place on measuring rod.

Set dial gauge (3 mm measuring range) to 0 with a 2 mm bias.
Place the gauge block plate MP3-405/17 (corresponds to VW 385/17 in figure V39-1881) on the secondary shaft head Anchor “Setting the secondary shaft”.
Remove master setting and insert measuring rod in the housing. The locating disc VW 385/3 should be towards the final drive cover.

Place the final drive cover and tighten the 4 screws to 25 Nm.
With the movable adjusting ring, move the 2nd locating disc VW 385/2 outwards until the measuring rod can still just be turned by hand.
Turn the measuring rod till the dial gauge indicator points towards the secondary shaft head and is at maximum deflection (reversing point).

Measurement in following example: “e” = 0.16 mm (red number range).
Note
- universal measuring rod, check again whether the dial gauge - with the master setting VW 385/30 mounted - is at with the 2mm bias. If not, adjust the setting.