Air conditionerProperties of refrigerant R 134a
Properties of refrigerant R 134a
Heating, Air conditioning · Heating, Air conditioning · Properties of refrigerant R 134a and of the refrigerant oil · Superb · Edition 10.01
| Colour |
|---|
| As a vapour and liquid, refrigerant is as colourless as water, and as a gas it is invisible. |
| Vapour pressure |
|---|
| In a fully filled and closed reservoir, the vapour refrigerant that evaporates on the surface is of the same volume which again liquifies when the vapour particles fuse. This balanced status is created under pressure and is frequently called vapour pressure. The vapour pressure is temperature dependent. |
| Pressure (overpressure) |
|---|
| Temperature in °C | MPa | bar |
|---|
| -30 | 0 | 0 |
| -20 | 0,03 | 0,3 |
| -10 | 0,1 | 1,0 |
| 0 | 0,19 | 1,9 |
| +10 | 0,31 | 3,1 |
| +20 | 0,47 | 4,7 |
| +30 | 0,67 | 6,7 |
| +40 | 0,91 | 9,1 |
| +50 | 1,22 | 12,2 |
| +60 | 1,58 | 15,8 |
| +70 | 2,02 | 20,2 |
| Solubility of the refrigerant oil |
|---|
| The special refrigerant oil (poly-alkylene-glycol oil) required for lubricating the cylinder walls also flows to a small extent in the refrigerant circuit and mixes with refrigerant R 134a. |
| Air displacement as a result of gaseous refrigerant |
|---|
| Refrigerant gas is heavier than air and therefore disperses along the floor. It gathers in depressions where it displaces the available air. |
| Environmental compatibility |
|---|
| Refrigerant R 134a contributes to the greenhouse effect when released into the earth atmosphere. However, the greenhouse effect of refrigerant R 134a is considerably less than that of refrigerant R12. |
| Toxicity |
|---|
| Up to a temperature of 101 °C refrigerant is non-toxic and has no adverse effects on the human body provided the instructions for use of refrigerant R 134a are observed. It is odourless, non-irritant and is therefore panicproof. |
| Refrigerant gas or vapour has no influence on foodstuff. It does not become toxic or unfit for human consumption. |
| Behaviour with plastics |
|---|
| Refrigerant is a solvent for certain plastics. These dissolved plastics may be eliminated during cooling in the expansion valve. The valve blocks. Therefore only use original spare parts! |
| Behaviour with metals |
|---|
| In pure condition refrigerant R 134a is chemically stable and does not corrode iron and aluminium. Contaminations of the refrigerant, e.g. with chlorine compounds, may result in certain metals and plastics being corroded. This may lead to choking, leaks or other deposits on the compresssor piston. |
| Critical temperature/critical pressure |
|---|
| Up to a gas pressure of 3.95 MPa (39.5 bar) overpressure (this corresponds to a temperature of 101 °C) refrigerant R 134a remains chemically stable, above this temperature the refrigerant decomposes (see flammability). |
| Water content |
|---|
| Water is only soluble in very small quantities in the liquid refrigerant. As opposed to this refrigerant vapour and water vapour mix in any proportion. |
| Water possibly present in the system is conveyed through the refrigerant circuit as drops, once the dessicator in the fluid reservoir has become saturated. The function of the dessicator is no longer guaranteed. This water flows to the nozzle of the expansion valve and turns to ice. This reduces the efficiency of the cooling. |
| Water destroys the air conditioning system, as acids are produced under high pressures and temperatures in combination with other contaminations. |
| Flammability |
|---|
| Refrigerant is non-flammable. On the contrary it has a fire-retardant or fire extinguishing effect. Refrigerant decomposes when brought into contact with flames or red-hot surfaces. UV light also splits the refrigerant (generated during electrical welding). This results in toxic fission products (hydrogen fluoride and traces of carbonyl fluoride and fluorine), which give adequate advance warning as they irritate the mucous membranes. |
| Filling factor |
|---|
| The reservoir must also include vapour space in addition to the fluid space. As the temperature rises the fluid expands. The space filled with vapour becomes smaller. At a given moment there will only be fluid left in the reservoir. After this only a minor temperature increase is required to generate very high pressures in the reservoir as the fluid can no longer expand because there is no more space. The resulting forces are great enough to burst the reservoir. In order to ensure a reservoir is not over-filled, the pressure gas regulations stipulate how many kilos of refrigerant may be filled per litre inside volume of the reservoir. This “filling factor” multiplied by the inside volume indicates the authorised filling content. For refrigerant R 134a, it is 1.15 kg/l. |
| Evidence of leaks |
|---|
| The refrigerant circuit may start leaking because of external damage. Because of the small amount of leaked refrigerant evidence of minor leaks can only be detected with an electronic leak detector. |
38 Heating & A/C