Connection diagram for rinsing cycle
- Make
- Skoda
- Model
- Superb
- Section
- Heating, Air conditioning › Connection diagram for rinsing cycle
Air conditionerConnection diagram for rinsing cycle
Connection diagram for rinsing cycle
Note
- The arrows in the Fig point towards the flow direction of the refrigerant during the purging process (refrigerant now flows out during the purging process against the flow direction of the air conditioning, therefore the high-pressure side of the service position for the air conditioning system is connected to the low-pressure connection of the refrigerant circuit, which leads to the compressor.
- VAS6338/31.

- Service position for the air conditioning system
with electronic and flush program or with flushing system
use a service position for the air conditioning system without a flush program, perform the work procedure manually (bleed, flush three times, at least 4 kg each time and drain the refrigerant again) - Refrigerant hose of service position for the air conditioning system
from the high-pressure side of the service position for the air conditioning system (usually red in colour) to the connection for the low-pressure side of the compressor (large diameter) - Adapter to connection for the low-pressure side
depending on different versions of the vehicle
adapter set for passenger vehicles VAS 6338/1 - Connection for the low-pressure side of the refrigerant circuit
depending on different versions of the vehicle - Connection to the catch pan
- Adapter for bridge structure of the removed catch pan
adapter set for passenger vehicles VAS 6338/1 - Filling hose for cooling medium
adapter set for passenger vehicles VAS 6338/1 - Adapter for bridge structure of the removed catch pan
adapter set for passenger vehicles VAS 6338/1 - Connection to the catch pan
- Evaporator
- Fitting location of the throttle
Throttle is removed
Remove throttle Chapter “Removing and installing throttle” - Screwed connection in the refrigerant line
screw together again after removing the throttle - Condenser
- Connection for the high-pressure side of the refrigerant circuit
e. g VAS 6336/1 or VAS 6337/1 (different versions and different design) - Adapter to connection for the high-pressure side of the refrigerant circuit
adapter set for passenger vehicles VAS 6338/1 - Filling hose of flushing system for the refrigerant circuits
from connection to high-pressure side of the compressor in the refrigerant circuit (smaller diameter) to inlet of flushing system for the refrigerant circuits - Flushing system for the refrigerant circuits
e. g VAS 6336/1 or VAS 6337/1 (different versions and different design)
with filter, transparent glass, securing vent, heating, refrigerant reservoir etc. (depending on the design)
depending on the design of the service position for the air conditioning systems and the flushing system for the refrigerant circuits, a non-return valve can be installed on the outlet of the flushing system for the refrigerant circuits (during purging process ensure correct flow direction of the cooling medium) - Hose for cooling medium of service position for the air conditioning system
from low-pressure side of the service position for the air conditioning systems (usually blue in colour) to outlet of flushing system for the refrigerant circuits
Parts & tools for this job For Skoda Superb