Clean refrigerant circuit with refrigerant R134a (flush)
- Make
- Skoda
- Model
- Superb
- Section
- Heating, Air conditioning › Clean refrigerant circuit with refrigerant R134a (flush)
Clean refrigerant circuit with refrigerant R134a (flush)
- In order to remove impurities (e. g. abrasion from defective compressor) as well as aged refrigerant oil in a clean refrigerant-saving and environmentally friendly manner, without demanding installation, the refrigerant circuit is flushed out with refrigerant R134a or is blown through with compressed air and nitrogen.
| The refrigerant circuit must be flushed with refrigerant R134a, if: |
|---|
| Dirt or other contaminations in the refrigerant circuit are present.when evacuating a tight refrigerant circuit the vacuum gauge is not constant (there is humidity in the refrigerant circuit and builds up pressure).the refrigerant circuit was open beyond standard assembly time (e.g. after an accident).pressure and temperature measurements in the circuit indicate that there is humidity in the refrigerant circuit.There is a doubt about the oil volume in the refrigerant circuit.the air conditioning compressor needed to be replaced because of internal damage (e.g. noise or no output).required for the respective vehicle after replacing one of the components of the Workshop Manual. |
- Service position for the air conditioning systems with flushing system VAS 6337 or VAS 6380. For these service positions for the air conditioning systems, the auxiliary function is available and the necessary flushing system for coolant circuit
- Adapter set for passenger vehicles VAS 6338/1
| Preliminary work |
|---|
| Drain refrigerant circuit. Remove the air conditioning compressor Chapter “Removing and installing compressor holder or dismantling and fitting the compressor to the holder”.In order to accelerate the flow of the refrigerant during flushing:Remove the catch pan with the dessicator insert Chapter “Repairing components of the refrigerant circuit” and attach again the lines. To do so use the adapter and the filling hose from the adapter set for passenger vehicles VAS6338/31.Remove throttle Chapter “Removing and installing throttle” and connect again the pipes of the cooling medium. |
| Refrigerant |
|---|
| Check volume of refrigerant in the service position for air conditioning system, there must be at least 7 kg of refrigerant R134a.30 mins before the first purging process or switching on the heating for the middle refrigerant bottle located in the service position (pressure in the middle refrigerant bottle increases) and before the first suctioning procedure switch off the heating again during the purging process.Empty the reservoir for the old refrigerant oil fitted in the service position.Connect the intake hose (high-pressure side) of the service position for the air conditioning system with adapter to the low-pressure line, that leads to the compressor (cable with larger diameter).Connect return-flow hose (low-pressure side or suction side) of the service position for the air conditioning system to the outlet of the flushing system for the refrigerant circuits.Connect inlet of flushing system for the refrigerant circuits with adapter to high-pressure line, that leads to the compressor, (cable with smaller diameter). |
Note
- Components are always flushed through against the flow direction of the refrigerant in the air conditioning.
- During the purging process dirt from the refrigerant circuit gets into the flushing system for the refrigerant circuits, which is caught by the installed filter and dessicator. Depending on contamination, replace these components at intervals according to operating instructions of the service position of the air conditioning systems or the flushing system for the refrigerant circuits.
- Depending on the type and intensity of the contamination of the flushed refrigerant circuit, the filter of the flushing system for the refrigerant circuits must be replaced no later than after 5 to 10 flushing cycles (vehicles flushed thoroughly). If a very dirty refrigerant circuit is flushed out (the refrigerant oil from the refrigerant circuit is black and viscous or there is swarf in the refrigerant circuit), the filter is replaced after flushing the refrigerant circuit. If the refrigerant circuit is very dirty, it is also recommended to once again flush the refrigerant circuit after changing the filter.
- Depending on the type of contamination (aged refrigerant oil and compressor wear), the contamination is deposited on the sight or inspection glass of the flushing device for refrigerant circuits. After the purging process, clean the glass or the inspection holes and check that the refrigerant circuit is once again flushed.
Switch on the service position and flush refrigerant circuit (a flushing cycle with three purging processes last approx. 1 to 1.5 hours).
Note
- The flushing of the refrigerant circuit is performed according to operating instructions of the service position of the air conditioning systems with flushing system.
- 3 of refrigerant oil. If during an installation the refrigerant coolant is flushed out with a greater quantity of oil, you must empty the container for the used oil after completing the first purging process.
- During the purging process the total volume of refrigerant oil from the refrigerant circuit is washed out of the refrigerant circuit (up to minor residue).
Observe the return of the refrigerant out of the refrigerant circuit. Only when clear and colourless refrigerant flows through the glasses or inspection holes of the flushing system for the refrigerant circuits, is the refrigerant circuit clean.
| The sequence of the purging precess (automatically moves across to the program of the service position for the air conditioning system) |
|---|
| After switching on, first the rinsing circuit is drained off (refrigerant circuit with connecting hoses and the flushing system for coolant circuit) and after this the tightness of the flushing system is checked (depending on the version of the service position or if necessary another manual switch-over, see operating instructions of the service position of the air conditioning systems).In the drained refrigerant circuit, the corresponding specific volume of coolant (e. g. 4 kg) is filled in via the high-pressure side of the service position (against the normal flow direction of the air conditioning, on the low-pressure side of the refrigerant circuit of the vehicle). Depending on the version of the service position of the air conditioning systems so much coolant can be filled in, until the rinsing circuit is filled up with refrigerant. This is determined in such a way that for a given period of time no coolant can enter.After topping up with the determined specific volume of coolant for example the heating of the flushing system is switched on depending on the version of the service position for the air conditioning systems and the flushing system of the refrigerant circuits (only if the refrigerant is drained off in gaseous condition from the flushing system for the refrigerant circuits).After extraction of the refrigerant, the heating of the flushing system is switched off (if it is an integral part of the station) the refrigerant circuit is again briefly bled depending on the version and after the ventilation, the refrigerant oil suctioned out of the refrigerant circuit, is expelled out of the service position for the air conditioning system.The filling, the extraction and the bleeding procedure is repeated twice (it must be performed three times).After completing the purging process: After completing, check the transparent glass or the inspection holes of the flushing system. If dirty, clean the purging process in accordance with the operating instructions of the flushing system and once again perform a check of the purging process (it lasts only one purging process, about 30 minutes).Evacuation of the vehicle refrigerant circuit using the service station (no overpressure should be present in the refrigerant circuit, i.e. briefly evacuate the refrigerant circuit again before switching off).Install a new throttle and catch pan with the dessicator insert.Depending on the fault:Replace AC compressor or drain out the remaining refrigerant oil from the removed AC compressor and fill in a certain quantity of new refrigerant oil Chapter “Refrigerant R134a”. |
Note
- The recommended volume of refrigerant oil is already available in the original part of the AC compressor.
Completely assemble again the refrigerant circuit, bleed and top up in accordance with the specifications.
Set the air conditioning again to operate and perform a functional test.
Parts & tools for this job For Skoda Superb
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Superb cabin filter
As an Amazon Associate we earn from qualifying purchases.