DTC
|
Diagnostic Trouble Code Storage Condition
|
B0012
|
Driver Airbag Squib Circuit (Stage 1) High Voltage
|
- Short to voltage in circuit to control unit terminal 25, 26 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0012
|
Driver Airbag Squib Circuit (Stage 1) Low Voltage
|
- Short to ground in circuit to control unit terminal 25, 26 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0012
|
Driver Airbag Squib Circuit (Stage1) Open
|
- Circuit interruption to control unit terminal 25, 26 (XC17)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0012
|
Driver Airbag Squib Circuit (Stage1) High Resistance
|
- Interruption in circuit to control unit terminal 25, 26 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0012
|
Driver Airbag Squib Circuit (Stage1) Low Resistance
|
- Short circuit in wiring harness to control unit terminal 25, 26 (XC 17) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0012
|
Driver Airbag Squib Circuit (Stage 1) Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 25, 26 (XC17) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage 2) High Voltage
|
- Short to voltage in circuit to control unit terminal 23, 24 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage 2) Low Voltage
|
- Short to ground in circuit to control unit terminal 23, 24 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage2) Open
|
- Circuit interruption to control unit terminal 23, 24 (XC17)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage 2) High Resistance
|
- Interruption in circuit to control unit terminal 23, 24 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage 2) Low Resistance
|
- Short circuit in wiring harness to control unit terminal 23, 24 (XC17) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0013
|
Driver Airbag Squib Circuit (Stage 2) Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 23, 24 (XC17) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC17)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 27, 28 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 27, 28 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit Open
|
- Circuit interruption to control unit terminal 27, 28 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit High Resistance
|
- Interruption in circuit to control unit terminal 27, 28 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 27, 28 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0014
|
Driver Side Airbag Squib Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 27, 28 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 27, 28 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 25, 26 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 25, 26 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit Open
|
- Circuit interruption to control unit terminal 25, 26 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit High Resistance
|
- Interruption in circuit to control unit terminal 25, 26 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 25, 26 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0015
|
Driver Pretensioner Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 25, 26 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 25, 26 (XC18)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage 1) High Voltage
|
- Short to voltage in circuit to control unit terminal 15, 16 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage 1) Low Voltage
|
- Short to ground in circuit to control unit terminal 15, 16 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage1) Open
|
- Circuit interruption to control unit terminal 15, 16 (XC17)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage1) High Resistance
|
- Interruption in circuit to control unit terminal 15, 16 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage1) Low Resistance
|
- Short circuit in wiring harness to control unit terminal 15, 16 (XC17) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B0019
|
Passenger Airbag Squib Circuit (Stage 1) Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 15, 16 (XC17) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 15, 16 (XC17)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 21, 22 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 21, 22 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit Open
|
- Circuit interruption to control unit terminal 21, 22 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit High Resistance
|
- Interruption in circuit to control unit terminal 21, 22 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 21, 22 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001C
|
Left Rollover Bar Squib Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 21, 22 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 21, 22 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 17, 18 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 17, 18 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit Open
|
- Circuit interruption to control unit terminal 17, 18 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit High Resistance
|
- Interruption in circuit to control unit terminal 17, 18 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 17, 18 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B001D
|
Right Rollover Bar Squib Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 17, 18 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC18)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage 2) High Voltage
|
- Short to voltage in circuit to control unit terminal 17, 18 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage 2) Low Voltage
|
- Short to ground in circuit to control unit terminal 17, 18 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage2) Open
|
- Circuit interruption to control unit terminal 17, 18 (XC17)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage 2) High Resistance
|
- Interruption in circuit to control unit terminal 17, 18 (XC17)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage 2) Low Resistance
|
- Short circuit in wiring harness to control unit terminal 17, 18 (XC17) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0020
|
Passenger Airbag Squib Circuit (Stage 2) Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 17, 18 (XC17) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 17, 18 (XC17)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 23, 24 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 23, 24 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit Open
|
- Circuit interruption to control unit terminal 23, 24 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit High Resistance
|
- Interruption in circuit to control unit terminal 23, 24 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 23, 24 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0021
|
Passenger Side Airbag Squib Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 23, 24 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 23, 24 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 19, 20 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 19, 20 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit Open
|
- Circuit interruption to control unit terminal 19, 20 (XC18)
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit High Resistance
|
- Interruption in circuit to control unit terminal 19, 20 (XC18)
- Above condition must be fulfilled for at least 1 s .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit Low Resistance
|
- Short circuit in wiring harness to control unit terminal 19, 20 (XC18) .
or
- Control unit recognises programming error
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0022
|
Passenger Pretensioner Circuit Shorted With Other Squib Circuit
|
- Short circuit in wiring harness to control unit terminal 19, 20 (XC18) .
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 19, 20 (XC18)
|
Remedy:
|
B0051
|
Squib Circuits Activated (Crash)
|
- The control unit has recognised a crash which required an airbag or seat belt pretensioner deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0052
|
Passenger Airbag Locked by SOD (Seat Occupied Detection)
|
- The control unit has recognised a vehicle crash, which required airbag deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0053
|
Deployment Commanded With Troublecodes in Squib Circuits Present
|
- The control unit has recognised a vehicle crash, which required airbag deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0054
|
Passenger Side Airbag Locked by SOD (Seat Occupied Detection)
|
- The control unit has recognised a vehicle crash, which required airbag deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0055
|
Side Airbag Activated
|
- The control unit has recognised a vehicle crash, which required airbag deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0058
|
Passenger Pretensioner Locked by SOD (Seat Occupied Detection)
|
- The control unit has recognised a vehicle crash, which required airbag deployment.
|
Concerned Terminals: -
|
Remedy:
|
B0081
|
SPPD Sensor Not Connected (Simple Passenger Presence Detection)
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
B0081
|
SOD PPD Sensor Malfunction (Seat Occupied Detection) (Passenger Presence Detection)
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
B0082
|
SOD CSD Sensor Malfunction (Seat Occupied Detection) (Child Seat Detection)
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
B0083
|
Left Or Middle EFS Not Programmed (Electronical Front Impact Sensor)
|
- Control unit recognises programming error
|
Concerned Terminals: -
|
Remedy:
|
B0083
|
Left Or Middle EFS Circuit High Voltage (Electronical Front Impact Sensor)
|
- Short to voltage in circuit to control unit terminal 30, 31 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 30, 31 (XC18)
|
Remedy:
|
B0083
|
Left Or Middle EFS Circuit Low Voltage (Electronical Front Impact Sensor)
|
- Short to ground in circuit to control unit terminal 30, 31 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 30, 31 (XC18)
|
Remedy:
|
B0083
|
Replace Left Or Middle EFS (Electronical Front Impact Sensor)
|
- The control unit recognises an internal airbag sensor malfunction
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 30, 31 (XC18)
|
Remedy:
|
B0083
|
Incorrect Left Or Middle EFS Installed (Electronical Front Impact Sensor)
|
- The control unit recognises an incorrect airbag sensor
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 30, 31 (XC18)
|
Remedy:
|
B0083
|
Invalid Data From Left Or Middle EFS (Electronical Front Impact Sensor)
|
- Sensor signal is out of range
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 30, 31 (XC18)
|
Remedy:
|
B0085
|
Driver SIS Not Programmed (Side Impact Sensor)
|
- Control unit recognises programming error
|
Concerned Terminals: -
|
Remedy:
|
B0085
|
Driver SIS Circuit High Voltage (Side Impact Sensor)
|
- Short to voltage in circuit to control unit terminal 39, 40 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 39, 40 (XC18)
|
Remedy:
|
B0085
|
Driver SIS Circuit Low Voltage (Side Impact Sensor)
|
- Short to ground in circuit to control unit terminal 39, 40 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 39, 40 (XC18)
|
Remedy:
|
B0085
|
Replace Driver SIS (Side Impact Sensor)
|
- The control unit recognises an incorrect side airbag sensor
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 39, 40 (XC18)
|
Remedy:
|
B0085
|
Incorrect Driver SIS Installed (Side Impact Sensor)
|
- The control unit recognises an incorrect side airbag sensor
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 39, 40 (XC18)
|
Remedy:
|
B0085
|
Invalid Data From Driver SIS (Side Impact Sensor)
|
- Sensor signal is out of range
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 39, 40 (XC18)
|
Remedy:
|
B0086
|
Passenger SIS Not Programmed (Side Impact Sensor)
|
- Control unit recognises programming error
|
Concerned Terminals: -
|
Remedy:
|
B0086
|
Passenger SIS Circuit High Voltage (Side Impact Sensor)
|
- Short to voltage in circuit to control unit terminal 41, 42 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 41, 42 (XC18)
|
Remedy:
|
B0086
|
Passenger SIS Circuit Low Voltage (Side Impact Sensor)
|
- Short to ground in circuit to control unit terminal 41, 42 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 41, 42 (XC18)
|
Remedy:
|
B0086
|
Replace Passenger SIS (Side Impact Sensor)
|
- The control unit recognises an incorrect side airbag sensor
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 41, 42 (XC18)
|
Remedy:
|
B0086
|
Incorrect Passenger SIS Installed (Side Impact Sensor)
|
- The control unit recognises an incorrect side airbag sensor
Effect:
- The system telltale is switched on.
|
Concerned Terminals: 41, 42 (XC18)
|
Remedy:
|
B0086
|
Invalid Data From Passenger SIS (Side Impact Sensor)
|
- Sensor signal is out of range
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 41, 42 (XC18)
|
Remedy:
|
B0099
|
Communication Malfunction Between Airbag And Telematic Unit
|
- Communication error between radio control unit and airbag control unit.
|
Concerned Terminals: -
|
Remedy:
|
B0670
|
Airbag Telltale Circuit Malfunction
|
- The control unit recognises an internal control unit malfunction
|
Concerned Terminals: -
|
Remedy:
|
B0975
|
CSD Telltale Circuit Malfunction (Child Seat Detection)
|
- The control unit recognises an internal control unit malfunction
|
Concerned Terminals: -
|
Remedy:
|
B1000
|
Electronic Control Unit Not Reusable
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
|
Concerned Terminals: -
|
Remedy:
|
B1000
|
Trouble Code Memory Full
|
- The control unit recognises an internal control unit malfunction
|
Concerned Terminals: -
|
Remedy:
|
U1327
|
Seat Occupied Detection System Voltage Low
|
- Short to ground in circuit to control unit terminal 38 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
U2050
|
SOD Not Programmed (Seat Occupied Detection)
|
- Control unit recognises programming error
|
Concerned Terminals: -
|
Remedy:
|
U2050
|
SOD Circuit High Voltage (Seat Occupied Detection)
|
- Short to voltage in circuit to control unit terminal 38 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
U2050
|
SOD Circuit Low Voltage (Seat Occupied Detection)
|
- Short to ground in circuit to control unit terminal 38 (XC18)
- Above condition must be fulfilled for at least 1 s .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|
U2050
|
Invalid Data from SOD (Seat Occupied Detection)
|
- Incorrect signal / value in circuit to control unit terminal 38 (XC18) .
|
Concerned Terminals: 38 (XC18)
|
Remedy:
|