DTC B2750 01: Horn Relay Secondary Circuit
Short to Battery
DTC B2750 02: Horn Relay Secondary Circuit
Short to Ground
DTC B2750 04: Horn Relay Secondary Circuit
Open
Diagnostic Fault Information
Circuit
Short to Ground
Open/High Resistance
Short to Voltage
Signal Performance
Horn Switch Signal
1
2
2
-
Horn Relay Control
B2750 02
B2750 04
B2750 01
-
Horn Control
2
2
1
-
Horn Ground
-
2
2
-
1. Horn Always On
2. Horn Inoperative
Circuit/System Description
The BCM provides a ground for the Horn PCB relay within the
underhood fuse block. The underhood fuse block will then provide B+
voltage to the horn control circuit, sounding the horn.
Conditions for Running the DTC
When the horn output is actively being requested by the BCM.
Conditions for Setting the DTC
B2750 01
The BCM detects a short to voltage in the horn relay control
circuit.
B2750 02
The BCM detects a short to ground in the horn relay control
circuit.
B2750 04
The BCM detects an open/high resistance in the horn relay control
circuit.
Action Taken When the DTC Sets
B2750 01, B2750 04
The horn will be inoperative.
B2750 02
The horn will sound continuously until the horn is disconnected or
when the horn overheats and becomes inoperative.
Conditions for Clearing the DTC
•
The DTC clears when the fault
is no longer detected.
•
The current DTC will become
history when the request for the output is removed.
•
The history DTC will clear
after 50 consecutive fault-free ignition cycles have
occurred.
Ignition ON, command the P12 horn ON and OFF with the scan tool.
The horn should turn ON and OFF when changing between the commanded
states.
Circuit/System Testing
1.
Ignition OFF, disconnect the
X2 harness connector at the X50A underhood fuse block.
2.
Connect a test lamp between
the control circuit terminal 25 and B+.
3.
Ignition ON, command the P12
horn ON and OFF with the scan tool. The test lamp should turn ON
and OFF when changing between the commanded states.
⇒
If the test lamp is always OFF, test the control
circuit for a short to voltage or an open/high resistance. If the
circuit tests normal, replace the K9 BCM.
⇒
If the test lamp is always ON, test the control
circuit for a short to ground. If the circuit tests normal, replace
the K9 BCM.
4.
If all circuits test normal,
replace the X50A underhood fuse block.