Test procedure
- Make
- Volkswagen
- Model
- LT Mk2
- Year
- 1996–2006
- Section
- Checking components and functions › Test procedure
Test procedure
Connect vehicle diagnosis, testing and information system VAS 5051Chapter. When doing this, the engine must be running at idling speed.
Note
- The individual control elements are activated for 30 seconds only. In the subsequent procedures you must make several entries within this period on vehicle diagnosis, testing and information system VAS 5051 and also read results. Therefore, read through the following steps first and familiarise yourself with the procedure.
Press key “03 - Final control diagnosis” on display.
Indicated on display:
Press key ← twice.
Press key “08 - Read measured value block” on display.
Press key 4 for “Display group number 4” and confirm entry with Q key.
| Display group | Display zone | Indicated on display |
|---|---|---|
| 4 | 1 | 840 rpm |
| 2 | 0.9° BTDC | |
| 3 | 0.9° BTDC | |
| 4 | 3 % |
The displays in display zones 3 and 4 must fluctuate within following control range:
Specification display zone 3:
Lower range 1° ATDC...4.8° BTDC.
Upper range 12.0...22.0° BTDC.
Specification display zone 4:
Lower range 2...5%.
Upper range 90...95%.
The measured value displays vary greatly due to the sluggishness of displays on vehicle diagnosis, testing and information system VAS 5051. Therefore ensure that the display zone 3 lowest value lies between 1.0 and 4.8 and the highest value lies between 12.0 and 22.0, and display zone 4 lowest value lies between 2 and 5 and the highest value lies between 90 and 95.
If the specifications are not obtained:
Check commencement of injection valve electrically → Chapter.
Parts & tools for this job For 1996 Volkswagen LT
- PARTGlow plugsSearch: Volkswagen LT 1996 glow plugs
- TOOLGlow plug socketSearch: glow plug socket
- TOOLDiesel compression testerSearch: diesel compression tester
As an Amazon Associate we earn from qualifying purchases.