A brake fluid leak is seen.
| Step | Test procedure | Result | Action |
|---|---|---|---|
| 0 | PRELIMINARY CHECKS Check whether the fault is accompanied by decreased braking efficiency Visually inspect the brake fluid level in the reservoir Op. 3330A12 | OK | |
| Decreased braking efficiency | End of diagnosis | ||
| Level too low |
| ||
| 1 | RESERVOIR LEAKAGE TEST Visually check that there are no leaks from the reservoir and the pipes | OK | |
| Leaks from the reservoir |
End of diagnosis | ||
| 2 | PUMP LEAKAGE TEST Visually check that there are no leaks of fluid from the brake pump and connectors | OK | |
| Leaks from the connectors in the area of the pump / ABS control unit |
End of diagnosis | ||
| Leaks from the connectors in the area of the pump / ABS control unit |
End of diagnosis | ||
| 3 | CHECK HOSES Visually inspect that there are no leaks from the flexible pipes | OK | |
| Leaks from the connectors or flexible pipe to the front brakes deteriorated |
End of diagnosis | ||
| Leaks from the connectors or flexible pipe to front brakes deteriorated |
End of diagnosis | ||
| 4 | RIGID PIPES CHECK Visually inspect that there are no leaks from the underbody rigid pipes | OK | |
| Leaks from the connectors or rigid pipes damaged |
End of diagnosis | ||
| 5 | CORRECT OPERATION CHECK Check that the fault is no longer present | OK | Incorrect selection of diagnostic procedure |
| Fault persists | Incorrect selection of diagnostic procedure |