Checking-adjusting: Lpg feed pressure
- Make
- Citroën
- Model
- Berlingo Factory Workshop Manual
- Year
- 1996–2002
- Section
- Air and fuel supply › Checking-adjusting: Lpg feed pressure
Checking-adjusting: Lpg feed pressure
ESSENTIAL: Before any operations Follow the safety instructions.
1. Recommended tools
[1] pressure checker (kit S.1602).
[2] pressure take-off connector (kit S.1602).
[3] 2nd stage pressure take-off connector (kit S.1602).
2. Checking and setting the pressure of the 1st stage
2.1. Preliminary operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Disconnect the solenoid valve (1).
Remove the plug (2).
Fit the tool [2] instead of and in place of the plug (2).
Tighten the tool [2].
2.2. Checking-adjusting
Connect output "a" of tool [1] to tool [2].
Connect output "b" of tool [1] to take-off (3) (pressure sensor take-off).
Reconnect the electrovalve (1).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Change to LPG mode.
Accelerate up to an engine speed of 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 1500 ± 50 mb
- New evaporator control valve: 1550 ± 50 mb
Adjust the value of pressure by adjusting the screw (4) (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
2.3. Additional operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Disconnect the solenoid valve (1).
Remove:
- The tool [1]
- The tool [2]
Refit and tighten the plug (2).
3. Checking and setting the pressure of the 2nd stage
3.1. Preliminary operations
Fit the tool [2].
Tighten the tool [2].
Uncouple the pipe (5).
Fit the tool [3] in place of the hose (5).
Couple the hose 5 to the tool 3.
3.2. Checking-adjusting
Connect output "a" of tool [1] to tool [3].
Connect output "b" of tool [1] to take-off (3) (pressure sensor take-off).
Reconnect the electrovalve (1).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Change to LPG mode.
Accelerate up to an engine speed of 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 1000 ± 10 mb
- New evaporator control valve: 1010 ± 10 mb
Adjust the value of pressure by adjusting the screw (6) (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
3.3. Additional operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Remove:
- The tool [1]
- The tool [2]
- The tool [3]
Connect the hose (5).
Refit and tighten the plug (2).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Check that the lpg mode operates correctly.