Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Instruments and warning lamps22 Locking, alarm and airbags23 Heating, air conditioning and audio
Citroën Berlingo Factory Workshop Manual (1996-2002)01 · Engine
01 · Engine

Checking-adjusting: Lpg feed pressure

Make
Citroën
Model
Berlingo Factory Workshop Manual
Year
1996–2002
Section
Air and fuel supply › Checking-adjusting: Lpg feed pressure
EngineChecking-adjusting: Lpg feed pressure

Checking-adjusting: Lpg feed pressure

Citroën Berlingo · Adjustments check · Ref. B1HE1UP0

Applies to: Dual fuel LPG and 1.4i 75 (TU3JP) from RPO 9002

ESSENTIAL: Before any operations Follow the safety instructions.

1. Recommended tools

Figure e5ap08bc

[1] pressure checker (kit S.1602).

Figure e5ap08cc

[2] pressure take-off connector (kit S.1602).

Figure e5ap210c

[3] 2nd stage pressure take-off connector (kit S.1602).

2. Checking and setting the pressure of the 1st stage

2.1. Preliminary operations

ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).

Figure b1hp1h2c

Disconnect the solenoid valve (1).

Remove the plug (2).

Fit the tool [2] instead of and in place of the plug (2).

Tighten the tool [2].

2.2. Checking-adjusting

Figure b1hp1h3p

Connect output "a" of tool [1] to tool [2].

Connect output "b" of tool [1] to take-off (3) (pressure sensor take-off).

Reconnect the electrovalve (1).

Activate the lpg feed circuit (see the relevant operation).

Start the engine.

Change to LPG mode.

Accelerate up to an engine speed of 3000 rpm.

Return to idle.

Wait 30 seconds.

Read the pressure Using tool [1].

Adjustment values:

  • Evaporator control valve which has already been used: 1500 ± 50 mb
  • New evaporator control valve: 1550 ± 50 mb
Figure b1hp1h4c

Adjust the value of pressure by adjusting the screw (4) (if necessary).

N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.

2.3. Additional operations

ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).

Disconnect the solenoid valve (1).

Remove:

  • The tool [1]
  • The tool [2]

Refit and tighten the plug (2).

3. Checking and setting the pressure of the 2nd stage

3.1. Preliminary operations

Fit the tool [2].

Tighten the tool [2].

Figure b1hp1h5c

Uncouple the pipe (5).

Fit the tool [3] in place of the hose (5).

Couple the hose 5 to the tool 3.

3.2. Checking-adjusting

Figure b1hp1h6p

Connect output "a" of tool [1] to tool [3].

Connect output "b" of tool [1] to take-off (3) (pressure sensor take-off).

Reconnect the electrovalve (1).

Activate the lpg feed circuit (see the relevant operation).

Start the engine.

Change to LPG mode.

Accelerate up to an engine speed of 3000 rpm.

Return to idle.

Wait 30 seconds.

Read the pressure Using tool [1].

Adjustment values:

  • Evaporator control valve which has already been used: 1000 ± 10 mb
  • New evaporator control valve: 1010 ± 10 mb
Figure b1hp1h7c

Adjust the value of pressure by adjusting the screw (6) (if necessary).

N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.

3.3. Additional operations

ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).

Remove:

  • The tool [1]
  • The tool [2]
  • The tool [3]

Connect the hose (5).

Refit and tighten the plug (2).

Activate the lpg feed circuit (see the relevant operation).

Start the engine.

Check that the lpg mode operates correctly.

Parts & tools for this job For 1996 Citroën Berlingo

As an Amazon Associate we earn from qualifying purchases.