Removing - refitting: CNG reservoir
- Make
- Citroën
- Model
- Berlingo Factory Workshop Manual
- Year
- 1996–2002
- Section
- Air and fuel supply › Removing - refitting: CNG reservoir
Removing - refitting: CNG reservoir
ESSENTIAL: Observe the safety requirements that apply to repairs on CNG circuits (see the relevant operation).
ESSENTIAL: All work on a gas powered vehicle should be performed in a ventilated area.
1. Recommended tools
[1] Gas leak detector (in aerosol form) LOCTITE 7100.
Set of gas circuit protection plugs (-).1605.C:
- [2A] gas circuit plug (-).1605.C1
- [2B] gas circuit plug (-).1605.C2
- [2C] tank valve plug (-).1605.C3
2. Removing
N.B.: The CNG tank can be removed even if it contains gas; Drain the CNG tank fully, while driving if possible.
2.1. Instructions to be followed
Handle the CNG tank with care:
- Do not scratch the CNG tank (risk of damage)
- Do not drop the CNG tank on the ground
- Do not roll the CNG tank in order to move it
- Do not drag the CNG tank on the ground
- If lifting equipment is used, use suitable straps to avoid damaging the CNG tank
2.2. Depressurising the circuit gnv
Open the flap.
Close the manual safety valve located on the CNG reservoir (as ""a"") (clockwise).
Start the engine.
Position the petrol/natural gas switch to natural gas mode.
Wait for the twin-fuel system to change automatically to petrol mode or for the engine to stall.
Switch off the ignition.
Disconnect the battery.
CAUTION: Check that the manual safety valve is closed.
2.3. Removing
Remove:
- The bolts (1)
- The casing (2)
ESSENTIAL: As CNG coming into contact with the skin can cause serious cold burns, it is essential to wear protective gloves and spectacles in order to avoid all risk of frostbite.
Eliminate all of the following risks in the proximity of the vehicle:
- Sparks (use of a grinder)
- Flames (use of a cutting torch)
- Slow combustion (lit cigarette)
Remove the collars and move aside the ventilation sleeves (3).
Disconnect the CNG tank electrovalve connector (as "b").
Slowly undo the unions (4) and (5).
N.B.: A little gas may escape into the atmosphere if the piping is still pressurised.
Remove:
- The 3 bolts (6)
- The 3 bolts (7)
- The straps (8)
- The CNG tank
N.B.: 2 persons are necessary for moving the CNG tank.
If the tank is stored or transported, blank the openings using threaded plugs [2c].
Place a Rilsan clip "c" on the manual safety valve to prevent it from being opened.
Store the CNG tank in a ventilated room.
3. Refitting
N.B.: 2 persons are required in order to reposition the CNG tank correctly.
CAUTION: Centre the CNG tank on its frame.
Check that the protectors (9) are positioned correctly.
CAUTION: There must not be any metal against metal contact between the CNG tank and the frame (10).
Refit the straps (8).
Tighten:
- The bolts (6) to 2,2 ± 0,2 daN.m
- The bolts (7) to 4 ± 0,4 daN.m
Recouple unions (4) and (5); Tighten unions (4) and (5).
4. Additional operations
CAUTION: Checking the sealing of the CNG piping and refitted unions; Using tool [1].
If the CNG tank is empty:
- Open the CNG tank manual valve
- Fill the CNG tank at the nearest CNG station
Spray the leak detector product [1] on the unions (4) and (5).
Check the sealing of the unions (4), (5); Using tool [1].
Should a leak occur:
- De-pressurise the system (see the relevant operation)
- Retighten the union
ESSENTIAL: Never re-tighten a connector under pressure.
Reposition the ventilation ducts.
Refit the CNG tank protection cover.
Parts & tools for this job For 1996 Citroën Berlingo
- PARTEngine gasket setSearch: Citroën Berlingo 1996 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.