Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Instruments and warning lamps22 Locking, alarm and airbags23 Heating, air conditioning and audio
Citroën Berlingo Factory Workshop Manual (1996-2002)01 · Engine
01 · Engine

Re-pressurising: CNG supply circuit

Make
Citroën
Model
Berlingo Factory Workshop Manual
Year
1996–2002
Section
Air and fuel supply › Re-pressurising: CNG supply circuit
EngineRe-pressurising: CNG supply circuit

Re-pressurising: CNG supply circuit

Citroën Berlingo · Removal-fitting · Ref. B1HGGVP0

Applies to: NVG dual fuel

ESSENTIAL: Never re-tighten or unscrew connectors under pressure.

N.B.: Before refitting CNG components, make sure that no impurities have penetrated inside the piping or into the threads of the unions.

1. Recommended tools

Figure e5ap08ec

[1] FRAMET DF9 or LOCTITE 7100 leak detector.

2. Re-pressurising

Close the natural gas supply circuit again and re-tighten the connectors (see the relevant operation).

Figure b1hp1ppc

2.1. Stage 1: Checking the low pressure

Open then rapidly reclose the manual safety valve at "a" on the CNG tank to obtain a partial pressure in the CNG circuit.

Carry out a sealing check on the previously removed unions, using the gas leak detection product [1] for 3 minutes.

ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system; Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.

2.2. Stage 2: High pressure check

CAUTION: If the tank contains less than three quarters (150 bars) of its capacity (see CNG gauge), it must be filled at the nearest CNG station in order to carry out the leak test at high pressure.

Open the CNG manual safety valve at "a".

Start the engine.

Change to CNG mode.

Stop the engine.

Carry out a sealing check on the previously removed unions, using the gas leak detection product [1] for 3 minutes.

2.3. Stage 4: Road test

Carry out a road test then carry out another sealing check.

3. Procedure for finding the origin of a CNG leak, following the emission of a smell of gas

It is compulsory that this operation is carried out in the open air, far from any source of ignition and with a safety perimeter marked out (two-colour tape or chain).

Procedure to be followed:

  • Switch off the ignition
  • Close the manual safety valve on the CNG tank
  • Ventilate the interior of the vehicle (open the doors)
  • Disconnect the battery negative cable
  • Open the manual safety valve on the CNG tank
  • Look for the leak on each union as well as on the pressure relief components using a leak detector

As soon as the leak is located, perform the following operations:

  • Close the manual safety valve on the CNG tank
  • Bleed the pipes by running the engine in CNG mode until the automatic switch to petrol mode
  • Make the necessary repairs

CAUTION: Never re-tighten a connector under pressure.

ESSENTIAL: Any faulty parts subjected to the high pressure must be replaced and not repaired. If the leak persists after a union has been tightened, replace the union.

After an idle phase of at least 3 hours, carry out a final detection of leaks before supplying to the customer.

4. Additional operations

To prevent all risks of corrosion after using a leak detector:

  • Rinse the unions with clean water
  • Dry the unions with compressed air

Parts & tools for this job For 1996 Citroën Berlingo