Re-pressurising: CNG supply circuit
- Make
- Citroën
- Model
- Berlingo Factory Workshop Manual
- Year
- 1996–2002
- Section
- Air and fuel supply › Re-pressurising: CNG supply circuit
Re-pressurising: CNG supply circuit
ESSENTIAL: Never re-tighten or unscrew connectors under pressure.
N.B.: Before refitting CNG components, make sure that no impurities have penetrated inside the piping or into the threads of the unions.
1. Recommended tools
[1] FRAMET DF9 or LOCTITE 7100 leak detector.
2. Re-pressurising
Close the natural gas supply circuit again and re-tighten the connectors (see the relevant operation).
2.1. Stage 1: Checking the low pressure
Open then rapidly reclose the manual safety valve at "a" on the CNG tank to obtain a partial pressure in the CNG circuit.
Carry out a sealing check on the previously removed unions, using the gas leak detection product [1] for 3 minutes.
ESSENTIAL: Should there be a leak of gas at the union, carry out a partial draining of the CNG system; Retighten the union, then restart the operations to re-pressurise the CNG supply circuit.
2.2. Stage 2: High pressure check
CAUTION: If the tank contains less than three quarters (150 bars) of its capacity (see CNG gauge), it must be filled at the nearest CNG station in order to carry out the leak test at high pressure.
Open the CNG manual safety valve at "a".
Start the engine.
Change to CNG mode.
Stop the engine.
Carry out a sealing check on the previously removed unions, using the gas leak detection product [1] for 3 minutes.
2.3. Stage 4: Road test
Carry out a road test then carry out another sealing check.
3. Procedure for finding the origin of a CNG leak, following the emission of a smell of gas
It is compulsory that this operation is carried out in the open air, far from any source of ignition and with a safety perimeter marked out (two-colour tape or chain).
Procedure to be followed:
- Switch off the ignition
- Close the manual safety valve on the CNG tank
- Ventilate the interior of the vehicle (open the doors)
- Disconnect the battery negative cable
- Open the manual safety valve on the CNG tank
- Look for the leak on each union as well as on the pressure relief components using a leak detector
As soon as the leak is located, perform the following operations:
- Close the manual safety valve on the CNG tank
- Bleed the pipes by running the engine in CNG mode until the automatic switch to petrol mode
- Make the necessary repairs
CAUTION: Never re-tighten a connector under pressure.
ESSENTIAL: Any faulty parts subjected to the high pressure must be replaced and not repaired. If the leak persists after a union has been tightened, replace the union.
After an idle phase of at least 3 hours, carry out a final detection of leaks before supplying to the customer.
4. Additional operations
To prevent all risks of corrosion after using a leak detector:
- Rinse the unions with clean water
- Dry the unions with compressed air