Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Doblò Factory Service Manual (2000-2010)19 · Wiring diagrams and electrical functions
19 · Electrical

Air conditioning - functional description

Make
Fiat
Model
Doblò Factory Service Manual
Year
2000–2010
Section
Climate control system › Air conditioning - functional description
Wiring diagrams and electrical functionsAir conditioning - functional description

AIR CONDITIONING - FUNCTIONAL DESCRIPTION

1.2 8v, 1.6 16v, 1.3 JTD 16V, 1.9 JTD 8V, 1.9 DIESEL · from 10/2000, up to 10/2000 · Climate control system

Functional description

The passenger compartment air fan is controlled by the relay R8 housed in the engine compartment junction unit B01.

The supply for the relay arrives from the battery at pin 1 of connector A and is protected by fuse F8, whilst the energizing of the coil is controlled by the ignition (INT/A) by the line protected by fuse F31 (junction unit under the dashboard B02 ).

The relay R8 directly supplies the fan N85, which operates at different speeds according to the ''load'' applied by the control knob H81 (supplied at pin 1 from the line for fuse F31 ). Operating the selector varies the number of resistances appiled (voltage divider) altering the fan speed.

The frost thermostat N86, which prevents the operation of the air conditioning compressor in case the actual evarporator ''freezes'', is located on the evaporator in the duct/distributor assembly.

In positions 1 to 4, the selector H81, closes an internal contact which enables the engagement of the air conditioning compressor.

The control panel has ideograms lit up when the side lights are switched on by lights G45 (A, B, C) supplied through the line protected by fuse F51 of the junction unit under the dashboard (

See E2010 SIDE LIGHTS / NO. PLATE LIGHTS

).

1.2 8v, 1.6 16v, 1.3 JTD 16V, 1.9 JTD 8V, 1.9 DIESEL · from 12/03

Functional description

The passenger compartment air fan is controlled by the relay R8 housed in the engine compartment junction unit B01.

The supply for the relay contact arrives from the battery at pin 1 of connector A and is protected by fuse F8, whilst the energizing of the coil is controlled by the ignition (INT/A) by the line protected by fuse F31 (junction unit under the dashboard B02).

When the climate control button H80 is pressed, relay R8 directly supplies the fan N85, which operates at different speeds according to the ''load'' applied by the control knob H81 (supplied at pin 1 from the line for fuse F31). Operating the selector varies the number of resistances appiled (voltage divider) altering the fan speed.

The frost thermostat N86, which prevents the operation of the air conditioning compressor in case the actual evarporator ''freezes'', is located on the evaporator in the duct/distributor assembly.

In positions 1 to 4, the selector H81, closes an internal contact which enables the engagement of the air conditioning compressor.

The control panel has ideograms lit up when the side lights are switched on by lights G45 (A, B, C) supplied through the line protected by fuse F51 of the junction unit under the dashboard B2.

Parts & tools for this job For 2000 Fiat Doblò