01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Grande Punto Factory Service Manual (2005-2012)22 · Fault diagnosis
22 · Diagnostics

Unpleasant climate control odours

Make
Fiat
Model
Grande Punto Factory Service Manual
Year
2005–2012
Section
Odours › Unpleasant climate control odours
Fault diagnosisUnpleasant climate control odours

UNPLEASANT CLIMATE CONTROL ODOURS

The climate control is working normally, but there are unpleasant smells in the passenger compartment.

Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation

First of all, check the following with the compressor ON:

- that the condensation drainage is not blocked;

- that condensation drains outside the passenger compartment;

- that the condensation drainage is not damaged;

- that the air/recirculation intake is not working;

- that there are no unpleasant smells coming from the outside by activating the recirculation

- that the smell does not come from the fan, ceramic resistor or speed regulator overheating (auto version).

Move on to Step 1

1. Condensation drainage blocked

2. The condensation is draining directly into the vehicle

3. Condensation drainage damaged

4. Recirculation not working

5. Smells coming from the outside

6. Smells from overheated fan, resistor or speed regulator

1. Clean the condensation drainage

2. Restore the correct operation of the condensation drainage

3. Replace the condensation drainage

4. Continue as indicated

See table L016 CLIMATE CONTROL RECIRCULATION NOT WORKING

5. Move on to Step 5

6. Replace damaged component

1POLLEN FILTER CHECKAll OKProblems encounteredOperation

Check the condition of the pollen filter

The pollen filter should be replaced at least once a year

Move on to Step 2Filter obstructed

Replace the filter element

Op. 5010B08 CLIMATE CONTROL OUTSIDE AIR PURIFYING (POLLEN) FILTER - R.R.

2AIR INLET DUCTS CHECKAll OKProblems encounteredOperation
Check the air inlet ducts: they should not be obstructed with dirt or unpleasant smelling substances.Move on to Step 3Ducts blockedWash the ducts.
3EVAPORATOR CHECKAll OKProblems encounteredOperation
With the engine started and the climate control system off (compressor OFF button), place the temperature knob in the max heat position and activate the fan. Check that the bad smell disappears.Move on to Step 6The smells persistMove on to Step 4
4RADIANT MASS CHECKAll OKProblems encounteredOperation

Check that the fins of the radiant mass are not blocked with dirt or other substances.

With the vehicle engine on, engine temperature warm or climate control system (temperature) knob set to max heat, check for fluid leaks inside the vehicle from the plastic tank or the radiant mass case

End of diagnosis

1. Radiant mass dirty or blocked

2. Fluid leak from the radiant mass

1. Clean the radiant mass

2. Replace the radiant mass

5AIR INTAKE CHAMBER CLEANLINESS CHECKAll OKProblems encounteredOperation
Check that there are no foreign bodies inside the air intake chamber. In particular, check that the seal between the air intake chamber and the engine compartment is perfect.End of diagnosis

1. Air intake chamber dirty.

2. Seal not perfect.

1. Clean the air intake chamber.

2. Refit the seal correctly

6EVAPORATOR REPLACEMENTAll OKProblems encounteredOperation

Replacement of the evaporator (check whether it is possible to clean it)

The use of Aircomatic equipment amd Wynn''s Airco-clean is recommended for disinfecting the mould on the evaporator and the directions should be followed.

End of diagnosisEvaporator covered in mould

Ask the customer whether it is the first time that the problem occurs, in which case the evaporator should be cleaned;

If the customer complains for the 2nd time more than 6 months later, continue to clean the evaporator, if it is less than 6 months replace the evaporator

Op. 5040C66 AIR CONDITIONING EVAPORATOR - R+R WITH AIR CONDITIONING CASING REMOVED

Parts & tools for this job For 2005 Fiat Grande Punto