CLIMATE CONTROL NOT HEATING
The climate control is working properly and sends air according to the preset flows but this air does not guarantee the required heating.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems encountered | Operation |
|---|---|---|---|---|
| Check that the engine coolant level is within the preset levels and that the refrigerant fluid circulates correctly in the system | Move on to Step 1 | Engine coolant level too low. | Restore the correct level checking that there are no leaks from the system. | |
| Refrigerant fluid not circulating correctly (thermostatic valve does not open sufficiently) | See fault diagnosis for thermostatic valve | |||
| 1 | CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATION | All OK | Problems encountered | Operation |
| With the engine on, the compressor off, in the manual function with the temperature knob at the maximum hot position. Select the recirculation button the the closed position and set the fan speed to 3 and front ventilation distribution. Using the diagnostic equipment check that the engine temperature reaches at least 70 °C | Move on to Step 4 | The temperature of the air coming out of the vents is not the desired one | Move on to Step 2 | |
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the Examiner diagnostic equipment and check that there are no errors at the engine temperature sensor | Move on to Step 3 | Error at the engine temperature sensor | See fault diagnosis for engine temperature sensor | |
| 3 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Check that the air mixture motor errors do not persist (after the self-learning procedure, if necessary) | End of diagnosis | Left air mixture actuator error | Replace the left air mixture motor Op. 5040D84 AIR CONDITIONING LEFT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |
| Right air mixture actuator error | Replace the right air mixture motor Op. 5040D86 AIR CONDITIONING RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |||
| 4 | CHECK ON CORRECT OPERATION OF KINEMATIC MECHANISM | All OK | Problems encountered | Operation |
| Check that the climate control flexible cables/kinematic mechanisms are working correctly | End of diagnosis | Operation of climate control flexible cables/kinematic mechanisms not correct | Replace the control unit and flexible transmission cables | |
The climate control is working properly and sends air according to the preset flows but this air does not guarantee the required heating.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems encountered | Operation |
|---|---|---|---|---|
| Check that the engine coolant level is within the preset levels and that the refrigerant fluid circulates correctly in the system | Move on to Step 1 | Engine coolant level too low. | Restore the correct level checking that there are no leaks from the system. | |
| Refrigerant fluid not circulating correctly (thermostatic valve does not open sufficiently) | See fault diagnosis for thermostatic valve | |||
| 1 | CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATION | All OK | Problems encountered | Operation |
| With the engine on, the compressor off, in the manual function with the temperature knob at the maximum hot position. Select the recirculation button the the closed position and set the fan speed to 3 and front ventilation distribution. Using the diagnostic equipment check that the engine temperature reaches at least 70 °C | End of diagnosis | The temperature of the air coming out of the vents is not the desired one | Move on to Step 2 | |
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Connect the Examiner diagnostic equipment and check
| Move on to Step 3 | Short circuit error at the air mixture actuators | Move on to Step 3 | |
| Implausible error at the left actuator | Replace the actuator Op. 5040D84 AIR CONDITIONING LEFT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |||
| Implausible error at the right actuator | Replace the actuator Op. 5040D86 AIR CONDITIONING RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |||
| Error at the engine temperature sensor | See fault diagnosis for engine temperature sensor | |||
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
| Check the continuity/insulation of the electrical connection for the air mixture actuator(s) | Move on to Step 4 | Electrical connection broken or not insulated | Restore the continuity/insulation of the electrical connection. | |
| 4 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Check that the air mixture motor errors do not persist (after the self-learning procedure, if necessary) | End of diagnosis | Left air mixture actuator error | Replace the left air mixture motor Op. 5040D84 AIR CONDITIONING LEFT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |
| Right air mixture actuator error | Replace the right air mixture motor Op. 5040D86 AIR CONDITIONING RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |||