01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Climate control recirculation automatic mode not working

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Climate control › Climate control recirculation automatic mode not working
Fault diagnosisClimate control recirculation automatic mode not working

CLIMATE CONTROL RECIRCULATION AUTOMATIC MODE NOT WORKING

The recirculation is not closed automatically when there is pollution.

Results of the tests
1CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODEAll OKProblems encounteredOperation

With the engine started, set the climate control system control unit to the AUTO position, adjust the temperature knob so that it reaches 22 °C, set the fan speed to 6 bars, then press the recirculation button (check that the recirculation warning light comes on). Then check, by feeling, that the air flow changes during the flap opening/closing function. Also locate the grille for the air intake casing in the engine compartment and check the intake of air in switch from recirculation to outside air intake

When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up

Move on to Step 2 1The LED with the recirculation symbol does not light up.Move on to Step 4
The LED with the recirculation symbol lights up, but the function is not activatedMove on to Step 2
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment and check that there are no errors at the air recirculation actuator.Move on to Step 6 1Errors at the recirculation actuator.Move on to Step 3 1
3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the Examiner diagnostic equipment connected, check the operation of the air recirculation through active diagnosisMove on to Step 6 1Air recirculation actuator not workingMove on to Step 4 1
4ELECTRICAL CONNECTIONS CHECKAll OKProblems encounteredOperation
Check that the electrical wiring connections are not loose. Remove the control from the dashboard support and disconnect the cable connector from the control unit and reconnect it correctly for check for any false contacts. Remove the glove compartment and disconnect/reconnect the electrical connection to the actuator.Move on to Step 5 1Electrical wiring connections loose

Restore the correct wiring connections. See

E6020 CONDIZIONATORE

Electrical connections not loose (but the LED with the recirculation symbol does not light up)

Replace the climate control node

Op. 5040D15 CONTROL UNIT WITH AUTOMATIC DUEL ZONE AIR CONDITIONER KNOBS AND BUTTONS R R

5RECIRCULATION MOTOR OPERATION CHECKAll OKProblems encounteredOperation

Then proceed as follows: with the engine running, manually engage the recirculation air intake function with the fan at the maximum speed. If the actuator works and the flap is driven, feel that the type of air flow alters during the movement. Deactivate the function by returning the actuator to the original condition. Identify the air intake casing grille on the vehicle and check by feeling the air intake with your hand in the switch from recirculation to outside air and vice versa. If the result of the check is positive, do not replace the actuator. To check further in case of doubts on the operation of the actuator, it is possible to carry out the check following the methods described in Test 5040DE if the air intake casing is easily accessible,

See Test 5040D AIR CONDITIONER CONTROLS

Move on to Step 6 1Incorrect operation of actuator

Replace the actuator

Op. 5040D75 AIR CONDITIONER RECIRCULATION FLAP CONTROL MOTOR R R

6RECIRCULATION MOTOR FLAP CHECKAll OKProblems encounteredOperation
Check that the air recirculation motor flap completes its travel without any hinderance.End of diagnosisFlap obstructed or damaged.Remove the air recirculation motor flap impediment or replace the flap, if damaged.