CLIMATE CONTROL TOO COLD
The control button activates the passenger compartment fan properly but the temperature of the air is not correct.
| Results of the tests | ||||
| 1 | SYSTEM PRESSURE CHECK | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Connect the climate control system to the special repressurizing equipment and check the pressures See Test 5040OB AIR- CONDITIONER SYSTEM OPERATION CHECK (PRESSURES) | Move on to Step 2 | System pressure not correct. | Restore the correct system pressure value | |
| Refrigerant pressurizing too low or too high | Restore the correct coolant level Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE | |||
| 2 | CHECK ON CORRECT MANUAL CONTROL OPERATION | All OK | Problems encountered | Operation |
Before starting, check the following conditions:
With the engine on, at ambient temperature (check using the diagnostic equipment that the passenger compartment temperature and evaporator sensors indicate about 20 °C), with the vehicle compressor on, adjust the temperature to maximum cold LO, the distribution to the front position, the speed for the selector to the 2nd speed and the outside air intake function. After about 5 minutes in these conditions, check using the diagnostic equipment that the temperature values for the passenger compartment and evaporator sensors show a decrease: from the initial temperature of about 20 °C (ambient temp.) and gradually decrease to a temperature of about 3.5°C for the evaporator sensor and between 6 and 10°C for the front distribution air vents. Check whether the temperature of the air coming out of the vents actually alters (becoming colder) | Move on to Step 5 | The air coming out of the climate control vents does not feel colder | Move on to Step 3 | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Connect the Examiner diagnostic equipment and check:
| Move on to Step 5 | Error at the outside temperature sensor | Move on to Step 4 | |
| Error at the frost sensor | Move on to Step 4 | |||
| 4 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation of the electrical connection:
| Move on to Step 5 | Electrical connection broken or not insulated. | Restore the continuity/insulation of the electrical connection. | |
| 5 | PIPE AND FILTER CHECK | All OK | Problems encountered | Operation |
| Check that the air conditioning high and low pressure pipes are not blocked | Move on to Step 6 | Pipe from compressor to condenser obstructed. | Replace the pipe from the compressor to the condenser Op. 5040A50 PIPE FROM COMPRESSOR TO AIR CONDITIONER CONDENSER - R+R | |
| Pipe from condenser to drier filter obstructed | Replace the pipe from the condenser to the drier filter Op. 5040A52 PIPE FROM CONDENSER TO DEHYDRATING FILTER - R+R | |||
| Pipe from drier filter to expansion valve blocked | Replace the pipe from the drier filter to the expansion valve Op. 5040A54 PIPE FROM DEHYDRATING FILTER TO EXPANSION VALVE - R+R | |||
| 6 | CONDENSER CHECK | All OK | Problems encountered | Operation |
| Check that the condenser is not blocked or fouled with mud | Move on to Step 7 | Condenser blocked | Replace the condenser Op. | |
| Condenser fouled | Remove the fouling by washing | |||
| 7 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Check that the following errors do not persist:
| Move on to Step 8 | Outside temperature sensor error. | Replace the outside temperature sensor Op. 5010D12 OUTSIDE AIR TEMPERATURE SENSOR ON DOOR MIRROR - R+R FOLLOWING ELECTRICAL CIRCUIT CHECK | |
| Frost sensor error | Replace the frost sensor | |||
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems encountered | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists. | Search for the problem in the climate control flexible transmission cables/kinematic mechanisms | |
The control button activates the passenger compartment fan properly but the temperature of the air is not correct.
| Results of the tests | ||||
| 1 | SYSTEM PRESSURE CHECK | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Connect the climate control system to the special repressurizing equipment and check the pressures See Test 5040OB AIR- CONDITIONER SYSTEM OPERATION CHECK (PRESSURES) | Move on to Step 2 | System pressure not correct. | Restore the correct system pressure value | |
| Refrigerant pressurizing too low or too high | Restore the correct coolant level Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE | |||
| 2 | CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODE | All OK | Problems encountered | Operation |
Before starting, check the following conditions:
With the engine on, at ambient temperature (check using the diagnostic equipment that the passenger compartment temperature and evaporator sensors indicate about 20 °C), with the vehicle compressor on, place the control unit to AUTO, adjust the temperature to maximum cold LO, the distribution to the front position, the fan speed to 3 bars and the outside air intake function. After about 5 minutes in these conditions, check using the diagnostic equipment that the temperature values for the passenger compartment and evaporator sensors show a decrease: from the initial temperature of about 20 °C (ambient temp.) and gradually decrease to a temperature of about 3.5°C for the evaporator sensor and between 6 and 10°C for the front distribution air vents. Check whether the temperature of the air coming out of the vents actually alters (becoming colder) | End of diagnosis | The air coming out of the climate control vents does not feel colder | Move on to Step 3 | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Connect the Examiner diagnostic equipment and check:
| Move on to Step 5 | Error at the air mixture actuators | Move on to Step 4 | |
| Error at the outside temperature sensor | Move on to Step 4 | |||
| Error at the passenger compartment temperature sensor | Move on to Step 4 | |||
| Error at the frost sensor | Move on to Step 4 | |||
| 4 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation of the electrical connection:
| Move on to Step 5 | Electrical connection broken or not insulated. | Restore the continuity/insulation of the electrical connection. | |
| 5 | PIPE AND FILTER CHECK | All OK | Problems encountered | Operation |
| Check that the air conditioning high and low pressure pipes are not blocked | Move on to Step 6 | Pipe from compressor to condenser obstructed. | Replace the pipe from the compressor to the condenser Op. 5040A50 PIPE FROM COMPRESSOR TO AIR CONDITIONER CONDENSER - R+R | |
| Pipe from condenser to drier filter obstructed | Replace the pipe from the condenser to the drier filter Op. 5040A52 PIPE FROM CONDENSER TO DEHYDRATING FILTER - R+R | |||
| Pipe from drier filter to expansion valve blocked | Replace the pipe from the drier filter to the expansion valve Op. 5040A54 PIPE FROM DEHYDRATING FILTER TO EXPANSION VALVE - R+R | |||
| 6 | CONDENSER CHECK | All OK | Problems encountered | Operation |
| Check that the condenser is not blocked or fouled with mud | Move on to Step 7 | Condenser blocked | Replace the condenser | |
| Condenser fouled | Remove the fouling by washing | |||
| 7 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Check that the following errors do not persist:
| End of diagnosis | Left air mixture actuator error | Replace the left air mixture actuator Op. 5040D84 AIR CONDITIONING LEFT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |
| Right air mixture actuator error | Replace the right air mixture actuator Op. 5040D86 AIR CONDITIONING RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R.R | |||
| Outside temperature sensor error. | Replace the outside temperature sensor Op. 5010D12 OUTSIDE AIR TEMPERATURE SENSOR ON DOOR MIRROR - R+R FOLLOWING ELECTRICAL CIRCUIT CHECK | |||
| Passenger compartment temperature sensor error | Replace the passenger compartment temperature sensor | |||
| Frost sensor error | Replace the frost sensor | |||