Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Stilo Factory Service Manual (2001-2007)22 · Fault diagnosis
22 · Diagnostics

Climate control too cold

Make
Fiat
Model
Stilo Factory Service Manual
Year
2001–2007
Section
Climate control › Climate control too cold
Fault diagnosisClimate control too cold

CLIMATE CONTROL TOO COLD

The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.

Results of the tests
1CHECKING SYSTEM PRESSUREAll OKProblems metOperation
Connect the climate control system to the repressurizing equipment and check the system pressureContinue to Step 2System pressure incorrect.Restore correct system pressure.Op. 5040A10
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect an Examiner and check for errors:

  • in air mixing motors;
  • in treated air sensors;
  • in the frost sensor.
Continue to Step 4Air mixing motor damagedContinue to Step 3
Treated air sensor damaged.Continue to Step 3
Frost sensor damaged.Continue to Step 3
3CHECKING ELECTRICAL CIRCUITAll OKProblems metOperation

Check electrical connection continuity/insulation:

  • of air mixing motors
  • of treated air sensors;
  • of frost sensor.
Continue to Step 8Electrical connection interrupted or not insulated.Restore electrical connection continuity/insulation
4CHECKING PIPES AND FILTERAll OKProblems metOperation
Check high and low pressure pipes and air conditioning system filter are not blocked.Continue to Step 5Pipes from compressor to condenser blocked.Change the pipe from compressor to condenser Op. 5040A50
Pipes from compressor to condenser blocked.Change the pipe from condenser to filter Op. 5040A52
Pipes from compressor to condenser blocked.Change the pipe from filter to expansion valve Op. 5040S54
Pipes from compressor to condenser blocked.Replace the filter Op. 5040A44
5CONDENSER CHECKAll OKProblems metOperation
Check that the condenser is not blocked.Continue to Step 6Condenser blockedReplace the condenser Op. 5040A40
6EXPANSION VALVE CHECKAll OKProblems metOperation
Check that the expansion valve is working properlyContinue to Step 8Expansion valve not working properlyReplace the expansion valveOp. 5040B30
7CHECKING CORRECT OPERATION USING A TESTERAll OKProblems metOperation

Check errors do not persist:

  • in air mixing motors;
  • in treated air sensors;
  • in the frost sensor.
End of diagnosisAir mixing motor damaged

Change mixed air motor (if LH) Op. 5040D84

Change mixed air motor (if RH) Op. 5040D86

Air mixing motor damagedChange the treated air sensorOp. 5010D28
Air mixing motor damagedChange the frost sensorOp. 5040D22
8CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists

Change the climate control nodeOp. 5040D18

Search for the fault starting from another symptom'

Parts & tools for this job For 2001 Fiat Stilo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.