01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)19 · Wiring diagrams and electrical functions
19 · Electrical

Compressor engagement description

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Climate control system › Compressor engagement description
Wiring diagrams and electrical functionsCompressor engagement description

COMPRESSOR ENGAGEMENT DESCRIPTION

Automatic Air Conditioning

Description

The special button on the climate control system in the centre of the dashboard switches on the air cooling and dehumidification circuit, activating the air conditioning compressor.

The above button enables operation of the air cooling circuit, but actual compressor activation is also dependent upon activation of:

  • the frost thermostat sensor, located near the evaporator, which stops the engagement of the air conditioning if the temperature of the evaporator is too low;
  • the fan linear sensor, located on the coolant circuit that locks air conditioner activation if coolant pressure is too low or high;
  • the engine control unit that excludes compressor operation in accordance with engine management mode; e.g. in the case of high engine temperatures or high engine load (sudden acceleration).
Component codeDescriptionReference to the assembly
D008Front/climate control coupling
H081Climate control fan operation5040C
K087Lower mixed air temperature sensor5010D
K088Upper mixed air temperature sensor5010D
K089Passenger compartment air temperature sensor5010D
M070Climate control sytem control unit
N078Left mixed air flap actuator5040D
N079Right mixed air flap actuator5040D
N080Air distribution flap actuator5040D
N82Outside air/recirculation intake flap actuator5040D