Borg Warner Transfer Box Front Output Shaft Drive Flange Overhaul
TRANSFER BOX
2
OVERHAUL
FRONT OUTPUT SHAFT DRIVE FLANGE
Service repair no - 41.20.15/01
Remove
1. Using LRT-51-003 to restrain front output shaft
drive flange, remove and discard nut securing
drive flange to front output shaft.
2. Collect washer and seal.
3. Using LRT-99-500 if necessary, remove drive
flange from front output shaft.
Refit
1. Clean running surface of drive flange. Ensure
all traces of rubber are removed.
CAUTION: Do not use a metal scraper as
this may damage sealing surface.
2. Fit drive flange to front output shaft.
3. Fit seal, washer and new nut to front output
shaft.
4. Using LRT-51-003 to restrain drive flange,
tighten nut to 220 Nm. (162 lbf.ft)