landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

GENERAL SPECIFICATION DATA|Page 47 > < GENERAL SPECIFICATION DATA|Page 45
Page 26
background image

GENERAL SPECIFICATION DATA

3

INFORMATION

FUEL SYSTEM - Td5

Type

Direct injection from pressure regulated supply with

.................................................................................

cooled return flow

Pressure regulator setting

4 bar (58 lbf.in

2

)

................................................

Pump

Electric two stage submersible

................................................................................

Pump output

Low pressure

30 l/h (6.6 gal/h) at 0.5 bar (7.25 lbf.in

2

)

..........................................................

High pressure

180 l/h (39.6 gal/h) at 4 bar (58 lbf.in

2

)

..........................................................

Max consumption

30 l/h (6.6 gal/h)

.............................................................

Injectors

Electronic unit injectors

...........................................................................

Injector normal operating pressure

1500 bar (21750 lbf.in

2

)

..................................

Filter

In-line canister filter/water separator with water

.................................................................................

detection

COOLING SYSTEM - Td5

Type

Pressurised spill return partial flow, thermostatically

.................................................................................

controlled

Cooling fans

11 blade axial flow on viscous coupling and 11 blade

.....................................................................

axial flow electric

Electric cooling fan switching points

On

Vehicle speeds of 50 mph (80 km/h) and below while

...........................................................................

ambient temperature is 28

°

C (82

°

F) or above

Off

Vehicle speeds of 62.5 mph (100 km/h) and above or

...........................................................................

ambient temperatures of 25

°

C (77

°

F) and below

Coolant pump

Centrifugal impeller, belt driven from crankshaft

...................................................................

Thermostat

Waxstat with pressure relief valve

.......................................................................

Thermostat opening temperature

Initial opening

82

°

C (179

°

F)

..........................................................

Fully open

96

°

C (204

°

F)

...............................................................

Expansion tank cap relief valve operating pressure

1.4 bar (20.3 lbf.in

2

)

.........

CLUTCH - Td5

Type

Diaphragm spring, hydraulically operated with

.................................................................................

self-centering pre-loaded release bearing

Drive plate diameter

267 mm

.........................................................

Pressure plate diameter

270 mm

...................................................

GENERAL SPECIFICATION DATA|Page 47 > < GENERAL SPECIFICATION DATA|Page 45