Refrigerant charging (page 3 of 9)
- Make
- Mazda
- Model
- MX-5 (NC) Factory Workshop Manual
- Year
- 2006–2008
- Section
- Refrigerant System
Heating and air conditioningRefrigerant charging · page 3 of 9
Courtesy of MAZDA MOTORS CORP.
CAUTION: Close the manifold gauge valve immediately after stopping the vacuum pump. If the valve is left open, the vacuum pump oil will back flow into the refrigeration cycle and cause a decrease in the efficiency of the air conditioner.
- Start the vacuum pump and let it operate for 15 min .
- Verify that high- and low-pressure side readings of the manifold gauge are at -101 kPa {-760 mmHg, - 29.9 inHg} . Close each valve of the manifold gauge.
- Stop the vacuum pump and wait for 5 min .
- Inspect the high- and low-pressure side readings of the manifold gauge.
- If the reading has changed, inspect for leakage and then repeat from Step 7.
- If the reading has not changed, go to next step.
- Open the valve of the refrigerant tank.
- Weigh the refrigerant tank to charge the suitable amount of refrigerant.