Alhambra (1996-2010): Technical data
Also for this vehicle: Alhambra (2010-2020).
General
Diagnostics
Engine
Transmission
Steering & suspension
Brakes
Body & interior
Heating & A/C
Electrical
Choose Sections to see everything in a chapter, or a chapter title to start at its first page.
General
- Straightening jig › Straightening jig
- Galvanized body parts › Galvanized body parts
Air conditioning system with refrigerant R134a165 pages
- General notes on air conditioning systems
- Introduction
- Additional information
- Basics of air conditioning
- Physical basics:
- Heat always flows from warmer to colder material
- Pressure and boiling point
- Vapour pressure table for refrigerant R134a
- Refrigerant R134a
- Physical data of refrigerant R134a
- Critical point
- Environmental aspects of refrigerant R134a
- Characteristics of refrigerant R134a
- Trade names and designations
- Colour
- Vapour pressure
- Physical properties of R134a
- Effects on metal
- Critical temperature and critical pressure
- Water content
- Combustibility
- Charge factor
- Detecting leaks
- Refrigerant machine oil
- Properties of refrigerant oils
- Comfort
- Environmental aspects
- How air conditioning works
- General safety
- Product characteristics
- Handling refrigerants
- Wear protective glasses
- Wear protective gloves and apron
- Do not allow liquid refrigerant to come in contact with the skin
- Do not inhale refrigerant vapours
- Absolutely NO SMOKING
- Welding and soldering on refrigeration systems
- Pungent smell
- First aid
- Handling pressure vessels
- Do not heat above 50° C
- Do not apply uncontrolled heat
- Seal empty containers
- Safety instructions for using extraction and charging equipment
- Safety precautions for when working on vehicles with air conditioning and when handling refrigerant R134a
- Basics for working on refrigerant circuit
- O-rings
- Before operating the air conditioning system after recharging with refrigerant
- General information on refrigerant circuit
- Refrigerant circuit components
- Distribution of the refrigerant circuit components and their influence on the high-pressure and low-pressure sides
- Air conditioning system compressor with magnetic clutch:
- Air conditioner compressor without magnetic clutch
- Air conditioner compressor without magnetic clutch, with elastic drive coupling
- Condenser
- Evaporator
- Reservoir
- Restrictor
- Receiver
- Expansion valve
- O-rings
- Pipes and hoses in refrigerant circuit
- High-pressure safety valve
- Design of refrigerant circuit
- Refrigerant circuit with expansion valve and evaporator
- Refrigerant circuit with restrictor and reservoir
- Quick-release coupling connections in refrigerant circuit
- Extraction and charging valve with Schrader valve
- Extraction and charging valve, high-pressure side
- Extraction and charging valve, low-pressure side
- Switch and sender in refrigerant circuit and related connections
- High-pressure switch for air conditioning system F23
- High-pressure switch for magnetic clutch F118
- Low-pressure switch for air conditioning system F73
- Connections to valves for switches in the refrigerant circuit
- Air conditioning system pressure switch F129
- High-pressure sender G65
- Refrigerant pressure and temperature sender G395
- Refrigerant circulation solenoid valve N43
- A/C compressor regulating valve, air conditioning system N280
- Electrical components not installed in refrigerant circuit
- Control and regulating unit for air conditioning system J127
- Radiator fan control unit J293
- Temperature switch for evaporator E33
- Evaporator out-flow temperature sender G263
- Pressures and temperatures in the refrigerant circuit
- Refrigerant circuit with expansion valve
- Refrigerant circuit with restrictor and reservoir
- Test and measurement work that can be performed using a manometer
- Manometers enable the following test and measurement work
- A/C service and recycling equipment
- Classification of extraction systems in groups
- Charging devices that do not require a permit
- Notes to repairs on refrigerant circuit
- Statutory texts and instructions
- Statutes and regulations
- Recycling and refuse law
- Disposal of refrigerant and refrigerant machine oil
- Converting R12 refrigerant circuits to R134a refrigerant circuits and repairing them (retrofitting)
- Maintaining records on refrigerant
- Refrigerant circuit
- Important repair notes on air conditioning
- Retrofitting refrigerant circuit from R12 refrigerant to R134a refrigerant
- Working with the A/C service station
- Working with the A/C service station
- Important notes for working with the A/C service station
- Connecting an A/C service station for measuring and checking
- Draining refrigerant circuit using A/C service station
- Evacuating refrigerant circuit using A/C service station
- Charging refrigerant circuit using A/C service station
- Bringing air conditioning system into service after charging
- Charging container in A/C service station with refrigerant
- Draining air conditioning service station
- Detecting leaks in refrigerant circuit
- Searching for leaks in refrigerant circuits using <span class="tool">leak detector V.A.G 1796</span>
- Detecting leaks in refrigerant circuit using <span class="tool">leak detecting system VAS 6196</span> or <span class="to
- Clearing refrigerant circuit of contaminants
- Flush refrigerant circuit with compressed air and nitrogen.
- Blowing out refrigerant circuit
- Rinsing (cleaning) refrigerant circuit with refrigerant R134a
- Principle circuit diagrams for various rinsing circuits
- Adapters to create rinsing circuits
- Complaints
- Possible complaints about refrigerant circuit
- Test prerequisites:
- Possible complaints
- Connecting A/C service station
- For vehicles that have connections on both low-pressure and high-pressure sides of refrigerant circuit
- Connecting A/C service station for measuring and checking
- Checking pressures on vehicles
- Checking pressures in refrigerant circuit (using A/C service station)
- Test prerequisites
- Checking pressures
- Continuation of checking pressures
- Checking systems with a restrictor and reservoir (with internally regulated air conditioning system compressor)
- Specifications:
- Checking systems with an expansion valve and receiver (with internally regulated air conditioner compressor)
- Specifications:
- Checking systems with an expansion valve and receiver (without regulated air conditioner compressor)
- Test prerequisites
- Checking
- Specifications
- Checking with restrictor, reservoir and A/C compressor regulating valve, air conditioning system N280 (with externally r
- Specifications:
- Checking with expansion valve, receiver and A/C compressor regulating valve, air conditioning system N280 (with external
- Specifications:
- Renewing components
- In the event of leaking or damaged components (apart from the air conditioner compressor, receiver or reservoir)
- If the refrigerant circuit was completely empty
- If there is still refrigerant in the refrigerant circuit
- Renewing air conditioner compressor
- Without needing to purge refrigerant circuit with compressed air and nitrogen (e.g. in cases of external damage during a
- Leaks or internal damage (e.g. noises or lack of power)
- Renewing receiver or reservoir, and restrictor
- After purging refrigerant circuit, e.g. due to moisture intrusion (because refrigerant circuit has stood open for a leng
- Without needing to purge refrigerant circuit with compressed air and nitrogen (e.g. damage in an accident); no refrigera
- Testing equipment and tools
- List of test equipment, tools and materials
- Tools and materials available from distribution centre or importer
- Tools and materials commercially available
- Tools to be manufactured locally
- Tools and materials available from distribution centre or importer
- Tools and materials commercially available
- Tools to be manufactured locally
- Glossary
Engine
Transmission
Steering and suspension
Brakes
Electrical
Heating and air conditioning
Body
Diagnostics