Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Body, rear32 Bonnet, flaps, cab, central locking33 Front door, central locking34 Rear door, sliding door, wing doors, central locking35 Sliding roof36 Bumper37 Glazing/window mechanism38 Exterior equipment39 Interior equipment40 Passenger protection41 Trim, noise insulation42 Seat padding, covers43 Heating44 Aux. heater/heater booster45 Air conditioner46 Instruments, GCI47 Infotainment48 Windscreen wipe/wash system49 Lights, lamps, switches outside50 Lights, lamps, switches inside, anti-theft system51 Wiring
SEAT Alhambra (1996-2010)01 · Technical data
01 · General

Pressure and boiling point

Make
SEAT
Model
Alhambra
Year
1996–2010
Section
Air conditioning system with refrigerant R134a › Pressure and boiling point
Technical dataPressure and boiling point

Pressure and boiling point

Heating, ventilation, air conditioning system · Air conditioning system with refrigerant R134a · General notes on air conditioning systems · Alhambra from 1996 · Edition 02.2006

The boiling points given in the table below are always based on an atmospheric pressure of 1 bar. If the pressure on a liquid is changed, its boiling point changes also.

It is well known that, for example, the lower the pressure, the lower the temperature at which water boils.

The vapour pressure curves for water and for refrigerant R134a show that at constant pressure and falling temperature the vapour becomes liquid (in the condenser), and that when pressure drops, the refrigerant changes from liquid into the vapour state (evaporator).

Vapour pressure curve for water

N87-0523
A Liquid B Gaseous C Vapour pressure curve for water 1 Pressure on the liquid in bar (absolute) 2 Temperature in ° C

Vapour pressure curve for refrigerant R134a

N87-0530
A Liquid B Gaseous D Vapour pressure curve for refrigerant R134a 1 Pressure on the liquid in bar (absolute) 2 Temperature in ° C

Parts & tools for this job For 1996 SEAT Alhambra